31-12-2023 - Original article
Zhuo Chen, Lingling An, Chien-Min Kao, Hsin-Hsiung Huang

The positronium lifetime imaging (PLI) reconstruction is a technique used in time-of-flight (TOF) positron emission tomography (PET) imaging that involves measuring the lifespan of positronium, which is a metastable electron-positron pair that arises when a PET molecule releases a positron, prior to its annihilation. We have previously developed a maximum likelihood (ML) algorithm for PLI reconstruction and demonstrated that it can generate quantitatively accurate lifetime images for a 570 ps (pico-seconds) TOF PET system. In this study, we conducted further investigations into the statistical properties of the algorithm, including the variability of the reconstruction results, the sensitivity of the algorithm to the number of acquired PLI events and its robustness to hyperparameter choices. Our findings indicate that the proposed ML method produces sufficiently stable lifetime images to enable reliable distinction of regions of interest. Moreover, the number of PLI events required to produce quantitatively accurate lifetime images is computationally plausible. These results demonstrate the potential of our ML algorithm for advancing the capabilities of TOF PET imaging.

31-12-2023 - Original article
Gregory R. Romanchek, Greyson Shoop, Shiva Abbaszadeh

The intrinsic resolution of Positron Emission Tomography (PET) imaging is bound by positron range effects, wherein the radioactive decay of the imaging tracer occurs at a disjoint location from positron annihilation. Compounding this issue are the variable ranges positrons achieve, depending on tracer species (the energy they are emitted with) and the medium they travel in (bone vs soft tissue, for example) – causing the range to span more than an order of magnitude across various study scenarios (~0.19 mm to ~6.4 mm). Radioisotopes, such as Zr-89, exhibit dual emissions of positron and prompt gammas, offering an opportunity for accurate tracer positioning as prompt gammas originate from the tracer location. These multi-emission radiotracers have historically suffered from increased noise corresponding to the third gamma interfering in annihilation gamma coincidence pairing. Recent advancements, however, have brought to light the unique property of annihilation gammas having scattering kinematics distinct from random gamma pairs. These properties are born from the singular quantum entanglement state available to the gamma pair following para-positronium decay which prescribes linearly orthogonal polarization. Such coherent polarization is not shared by prompt gamma emissions, offering an opportunity for their discrimination. We present an investigation into this technique, comparing the distribution of relevant scattering kinematics of entangled annihilation gammas and corresponding prompt gammas via a Monte Carlo simulation.

31-12-2023 - Original article
Konrad Skórkiewicz, Kazimierz Łątka, Anna Sowa-Staszczak, Alicja Hubalewska-Dydejczyk


Background: The aim of the study is to optimise the value of B parameter (β), which is used in the Q.Clear reconstruction in the imaging of neuroendocrine tumours. The study is divided into two parts: analysis of phantom data aiming at selection of the appropriate β for small changes, and then assessment of its impact on the quality of patients' images. The literature data on the optimal β value are inconclusive. Furthermore, the suggested values are not the result of the semi-quantitative assessment of Standard Uptake Volume (SUV) or the proper verification based on, for example, phantom studies using the known activity.

Results: The obtained results show that β increase raises the image uniformity in the Q.Clear reconstruction algorithm. Also, referring to the scientific reports, one can see that the signal to noise ratio in the image increases. The effect of the β change on the SUV mean and Contrast Recovery Coefficient (CRC) value is greatest for the smallest objects. The decrease of this parameter is also much higher with lower values of activity (a lower counts statistic in the PET system).

Conclusions: An increase of β has an adverse effect on the quality of a semi-quantitative assessment of SUV – as the parameter increases, the SUV and CRC values decrease. In the visual assessment, a satisfactory image quality is present with β = 450. Based on the analysis of SUV and CRC, an appropriate range of β values was selected as 350–450. At the selected range, a retrospective analysis of the clinical images of neuroendocrine tumours will be performed in the future and the impact of the change on the semi-quantitative analysis of pathological changes will be verified.

31-12-2023 - Original article
Majid Kazemi Kozani, Antoni Rucinski, Pawel Moskal

Hybrid in-beam PET/Compton camera imaging currently shows a promising approach to use of the quasi-real-time range verification technique in proton therapy. This work aims to assess the capability of utilizing a configuration of the Jagiellonian-positron emission tomography (J-PET) scanner made of plastic scintillator strips, so as to serve as a Compton camera for proton beam range verification. This work reports the production yield results obtained from the GATE/Geant4 simulations, focusing on an energy spectrum (4.2−4.6) MeV of prompt gamma (PG) produced from a clinical proton beam impinging on a water phantom. To investigate the feasibility of J-PET as a Compton camera, a geometrical optimisation was performed. This optimisation was conducted by a point spread function (PSF) study of an isotropic 4.44 MeV gamma source. Realistic statistics of 4.44 MeV PGs obtained from the prior step were employed, simulating interactions with the detector. A sufficient number of detected photons was obtained for the source position reconstruction after performing a geometry optimisation for the proposed J-PET detector. Furthermore, it was demonstrated that more precise calculation of the total deposited energy of coincident events plays a key role in improving the image quality of source distribution determination. A reasonable spatial resolution of 6.5 mm FWHM along the actual proton beam direction was achieved for the first imaging tests. This preliminary study has shown notable potential in using the J-PET application for in-beam PET/Compton camera imaging at quasi-real-time proton range monitoring in future clinical use.

31-12-2023 - Original article
Martyna Durak-Kozica, Ewa Stępień, Jan Swakoń, Paweł Moskal

Ultra-high dose rate (FLASH) proton radiotherapy is a promising treatment method for cancer patients. In our research, we want to compare the FLASH method with a conventional radiation method to show what effect they have on the biochemical structure of the tumour (3D model – spheroids) and the secretion of extracellular vesicles (EVs) and their cargo. The use of a modern method of creating spheroids will enable us to create conditions that are better able to mimic the tumour microenvironment.

31-12-2023 - Original article
Kamil Wawrowicz, Aleksander Bilewicz

Targeted Auger electron (AE) therapy exhibits great potency against small tumors and metastatic sites, which to date have no effective therapeutic options. However, the development of AE-based therapy is significantly limited due to the low availability of the most promising radionuclides, being the consequence of the poor cognition of relevant nuclear pathways and insufficient accessibility of highly enriched target materials and specific infrastructure. Therefore, the development and investigation approaches to overcome this limitation are highly complex and challenging. In the present paper, as a second group worldwide, we perform experimental evaluation of double-neutron capture of a 195mPt production – radionuclide showing the most favourable characteristics for targeted Auger electron therapy. For this purpose we investigated two-step iridium target activation via 193Ir(n,γ)194Ir(n,γ)195mIr(β-)➝195mPt. In presenting the current state of knowledge of identified production methods of this radionuclide, we highlight the limitations and challenges of cyclotron- and reactor-based approaches. With theoretical calculations followed by short-time irradiation with thermal neutron flux, we describe numerous nuclear and chemical difficulties associated with an investigated nuclear pathway. Obtained results reveal that research and commercial application of this method is significantly hindered or even impossible at the current state of knowledge. We point out the most critical limitations which need to be addressed for further consideration of the mentioned strategy. Therefore, 195mPt application for targeted Auger therapy still remains challenging and requires efforts to overcome the limitations.

31-12-2023 - Original article
Malgorzata Franz, Jan Franz

We present an algorithm for Monte Carlo simulations of positron tracks in biological materials. The algorithm takes into account the cross-section data for elastic and inelastic collisions between positrons and molecules and processes like direct annihilation, ionization and positronium formation. In the case of positronium formation, the algorithm considers the interactions of positronium with molecules. The algorithm can be used to identify the processes that are responsible to determine the lifetime of the positrons and their annihilation mechanism (direct or through positronium formation).

31-12-2023 - Original article
Paweł Konieczka, Lech Raczyński, Wojciech Wiślicki

This work describes an investigation into the utilization of convolutional neural networks for the classification of three-photon coincidences, focusing specifically on the para-positronium decay associated with a photon from nuclear deexcitation. The data were simulated using the Monte Carlo method, with scandium-44 as the source of β+ decays. A preprocessing method that allowed for initial cleaning of the training data was described. Subsequently, the parameters of the method for transforming tabular data into images were optimized. Finally, the created images were used to train a binary classifier using a convolutional network model. The developed data preprocessing step and transformation method into image format enabled the achievement of a precision rate of 52% at a sensitivity level of 95%, which was a 10 percentage point improvement compared to the logistic regression model.

31-12-2023 - Review article
Wolfgang A.G. Sauerwein, Thomas Fischer, Lucie Sancey, Camille Verry, Eiji Matsuura, Raymond L. Moss, Andrea Wittig

For decades, BNCT was seen as an attractive concept and an intellectual challenge with no prospect of widespread clinical application. This situation has changed fundamentally in just a few years with the progress in accelerator technology. Low-energy, high-intensity neutron sources can now be integrated into hospitals and are therefore directly available for patient treatment. A pioneer in this field is the development in Japan, where patients are already being treated in three hospitals, using in-house accelerator-based systems. Furthermore, the costs associated with the BNCT treatment of recurrent tumors in the head and neck area are already covered by the healthcare system. It is time to keep up to date with this technology and work to make it available to patients in high-tech medicine in other countries, especially in Europe and North America. This short article summarizes the main principles of BNCT, outlines some aspects of its history and mentions ongoing projects as well as some hurdles that need to be overcome, as well as the scientific questions that need to be addressed for wider availability of the method.

31-12-2023 - Original article
Roman Y. Shopa, Kamil Dulski

Positronium imaging is a new technique complementary to positron emission tomography (PET) based on the histogramming of time delay between the emission of a de-excitation photon, and a consequent electron-positron annihilation, to estimate the mean lifetime of orthopositronium (o-Ps), which depends on the local size of the voids, concentration of oxygen and bioactive molecules. We improve the resolution and reduce noise in positronium imaging by building time-delay spectra from the PET activity reconstructed by a 3-photon time-of-flight maximum likelihood expectation maximisation. The method was tested on the data measured for four human-tissue samples injected by 22Na and put in the Jagiellonian PET “Big barrel” scanner. Due to an ill-posed problem of fitting time-delay histograms, a multistage optimisation procedure was explored along with inferential analysis of the solution space. Run in parallel for multiple sets of initial guesses, we compared the second-order Levenberg-Marquardt algorithm (LMA) and the direct search Nelder-Mead simplex (NMS) method. The LMA proved to be faster and more precise, but the NMS was more stable with a higher convergence rate. The estimated mean o-Ps lifetimes in the 1.9 ns – 2.6 ns range were consistent with the reference results, while other fitting parameters allowed differentiation between the two patients who provided the tissue samples.

31-12-2023 - Original article
Magdalena Skalska, Martyna Durak-Kozica

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful analytical technique with great application potential in biomolecular matter research. SIMS measurements performed on biological samples, due to their complex structure and the content of many small and large atomic molecular compounds, suffer very rich and complex mass spectra of particles, which characterise the content and physio-chemical properties of examined samples. The proper description and understanding of features appearing in the spectra and, consequently, the final data confirming or rejecting the hypothesis put forward in the experiment, largely depend on the experimenter’s correct understanding of the technique itself and its limitations, knowledge of the tested material and its appropriate preparation. These issues mean that obtaining the right answer to the questions posed in the research hypothesis requires not only the correct conduct of experiments but also the appropriate processing of post-experimental data. This study aims to demonstrate the impact of various analytical and experimental procedures applied to reach proper conclusions from TOF-SIM measurements. These are different types of data normalization, the selection of a so-called region of interest (ROI), the selection of representative secondary ions and specific quantification methods, including a combination of experimental parameters. All these aspects were checked and discussed based on the results of the analysis of pancreatic β cells placed in a PBS solution on silicon wafers.

31-12-2023 - Original article
Aleksandra Jung, Katarzyna Matusiak

Selecting the proper dosimeter and methodology is crucial for accurate dose measurement, especially since the requirements are different for clinical and retrospective dosimetry. Regardless of the field-radiotherapy, X-ray diagnostic radiology or nuclear medicineefforts are continuously being made to improve radiation measurement accuracy through the development of new dosimeters, accurate calibration of instrumentation, training of staff, proper quality control and enhancement of radiation safety procedures. For instance, for retrospective dose estimation during radiation accidents, the selection of the appropriate material and knowledge of the intrinsic background signal of the selected material are crucial. In both clinical and retrospective dosimetry it is important to have adequate protocols as well as expertise in possible uncertainties, discussed here based on the authors own research.

31-12-2023 - Original article
Aleksander Khreptak, Magdalena Skurzok

Silicon drift detectors (SDDs) stand as a groundbreaking technology with a diverse range of applications, particularly in the fields of physics and medical imaging. This paper provides an analysis of the performance of SDDs as detectors for X-ray radiation measurement, shedding light on their exceptional capabilities and potential in medical imaging. Compared to conventional detectors, SDDs have several notable advantages. Their high efficiency in capturing X-rays allows them to provide outstanding sensitivity and accuracy in detecting even low-energy X-rays. In addition, SDDs exhibit significantly low electronic-noise levels, contributing to better signal-to-noise ratio and better data quality. Furthermore, their high resolution enables exact spatial localization of radiation sources, which is essential for accurate diagnosis. This research is devoted to the evaluation of efficiency and potential application of SDDs in X-ray spectroscopy, with particular emphasis on their application in medical imaging. We focus on evaluating the performance characteristics of SDDs, such as their linearity, stability and sensitivity in detecting X-rays. The aim is to highlight the suitability of SDDs for a wide range of applications.

31-12-2023 - Original article
Szymon Parzych

Recently, a novel PET imaging method – positronium imaging – has been proposed to take advantage of previously unused information about the positronium states. The first ex-vivo and in-vivo images of positronium characteristics were acquired with the J-PET tomograph. Complementary to the standard annihilation photon’s detection, positronium imaging also requires the registration of the prompt photon, which follows β+ decay. To that end, the introduction of an additional energy threshold for prompt γ registration and optimization of the energy window for annihilation γ are required. This simulation-based work undertook the mentioned task in the case of the modular J-PET scanner. Based on the 44Sc radioisotope, the energy window for annihilation photons was established to 0.2 MeV – 0.37 MeV, while the threshold for prompt gamma was fixed at 0.37 MeV, closely following the end of the energy window for annihilation photons.

31-12-2023 - Original article
Manish Das, Wiktor Mryka, Ermias Y. Beyene, Szymon Parzych, Sushil Sharma, Ewa Stępień, Pawel Moskal

The positronium imaging technique represents a potential enhancement of the PET imaging method. Its core principle involves employing a β+ radiation source that emits additional gamma (γ) quanta referred to as prompt gamma. Our aim is to evaluate the capability to differentiate between annihilation and prompt gamma emissions, a vital aspect of positronium imaging. For this purpose, the selected isotopes should enable high efficiency and purity in detecting both prompt gamma and annihilation gamma. The assessment of the efficiency in identifying prompt and annihilation photons for various isotopes, which are potentially superior candidates for β+ + γ emitters, is conducted through toy Monte-Carlo simulation utilizing the cross-section formula for photon-electron scattering. In this article, we have performed calculations for efficiency and purity values across different isotopes under ideal conditions and examined how these values evolve as we incorporate the fractional energy resolution into the analysis. Ultimately, the primary goal is to determine the energy threshold that optimizes both efficiency and purity, striking a balance between accurately identifying and recording events of interest while minimizing contamination from undesired events.

31-12-2023 - Original article
Wiktor Mryka, Manish Das, Ermias Y. Beyene, Paweł Moskal, Ewa Stępień

The application of PET scanners to proton-beam-therapy monitoring is a promising solution to obtain the range of the beam and hence the positions of a Bragg peak – maximum dose deposition point. A proton beam induces nuclear reactions in the tissue, leading to the production of isotopes that emit β+ radiation. This enables the imaging of the density distribution of β+ isotopes produced in the body, allowing the reconstruction of the proton beam range. Moreover, PET detectors may open the possibility for in-beam monitoring, which would offer an opportunity to verify the range during irradiation. PET detectors may also allow positronium imaging, which would be the indicator of the tissue conditions. However, the image of annihilation points does not represent the range of the proton beam. There are several factors influencing the translation from annihilation points to obtain the Bragg peak position. One of them is the kinetic energy of the positron. This energy corresponds to some range of the positron within the tissue. In this manuscript we estimate positron energy and its range and discuss its influence on proton therapy monitoring.

31-12-2023 - Original article
Ermias Y. Beyene, Manish Das, Martyna Durak-Kozica, Grzegorz Korcyl, Wiktor Mryka, Szymon Niedźwiecki, Szymon Parzych, Keyvan Tayefi, Rafał Walczak, Kamil Wawrowicz, Ewa Stępień, Paweł Moskal

The modular J-PET scanner, comprising 24 compact and versatile modules, each consisting of 13 plastic strips with four SiPM detectors at the ends, represents a powerful tool for clinical applications in nuclear medical imaging. This study presents preliminary results from the exploration of simultaneous dual-isotope imaging using the modular J-PET system. Our approach involved two isotopes: 68Ge, characterized by a ringlike shape, and 22Na, exhibiting a point-like shape. The imaging was based on double-coincidence and triple-coincidence events. In the double coincidence case, both isotopes contributed comparably, whereas in the triple coincidence case 22Na dominated due to the prompt gamma being emitted with 100% of positron emissions, unlike 68Ga, where the prompt gamma was emitted in only 1.3% of cases after positron emission. In this work we present direct 2γ images determined for two-signal events and images for three-signal events, with two signals from annihilation photons and one from a prompt gamma. These results showcase the preliminary findings from simultaneous dual-isotope imaging of 68Ga and 22Na isotopes using the modular J-PET scanner, which will be presented and discussed.

31-12-2023 - Original article
Tevfik Kaplanoğlu, Paweł Moskal

Total-body Positron Emission Tomography (PET) scanning is a promising new method for rapidly acquiring comprehensive wide-volume metabolic data with a lower radiation dosage compared to discrete whole-body PET imaging. PET scanners are generally used with Computed Tomography (CT) scanners to precisely understand tumor location and composition with the help of anatomical images. However, PET/CT sequential imaging methods for simultaneous total-body imaging are impractical for claustrophobic patients due to the enclosed gantry design and require large examination rooms because of the need for an exceptionally long patient table. To address this challenge, the Jagiellonian-PET Tomography (J-PET) Total-body scanner employs an innovative approach: utilizing both PET and CT devices on the same patient table but from different axes. The motion system of the J-PET Total Body scanner requires custom linear stages to move both PET and CT gantries. In this study, a novel cross-staged linear guiding solution is proposed by combining scanners on intersecting separable stages. The proposed sliding system is a combination of different machine elements and will be produced for the J-PET Total-body PET/CT Scanner. Concept designs are shown, and the proposed system is described. The application of the system for the J-PET total-body PET/CT scanner is discussed. The proposed solution is still in the development phase. The system holds the potential to achieve combining CT and PET scanners from different axes and enables motion artifact-free imaging for total-body imaging.

31-12-2023 - Original article
Anzori Georgadze, Shivani Shivani, Keyvan Tayefi Ardebili, Paweł Moskal

Total-body positron emission tomography (PET) instruments are medical imaging devices that detect and visualize metabolic activity in the entire body. The PET scanner has a ring-shaped detector that surrounds the patient and detects the gamma rays emitted by the tracer as it decays. Usually these detectors are made up of scintillation crystals coupled to photodetectors that convert the light produced by the scintillation crystal into electrical signals. Jagiellonian Positron Emission Mammograph (J-PEM) is the first J-PET prototype module based on a novel idea with a plastic scintillator and wavelength shifter (WLS). At the same time, it is a prototype module for the Total-Body J-PET system. J-PEM can be an effective system for the detection and diagnosis of breast cancer in its early stage by improving sensitivity. This can be achieved using the superior timing properties of plastic scintillators combined with the WLS sheets readout. In this paper we present an application of the Geant4 program for simulating optical photon transport in the J-PEM module. We aim to study light transport within scintillator bars and WLS sheets to optimize gamma-ray hit position resolution. We simulated a pencil beam of 511 keV photons impinging the scintillator bar at different locations. For each condition we calculated the value of the pulse height centroid and the spread of the photon distribution. Some free parameters of the simulation, like reflectivity and the effective attenuation length in the sheet, were determined from a comparison to experimental data. Finally, we estimated the influence of the application of WLS layer in the Total-Body J-PET on the scatter fraction. To optimize the performance of the J-PEM module we compared geometry WLS strips 50 and 83. It was found that spatial resolution was 2.7 mm and 3.5 mm FWHM for 50 and 83 WLS strips, respectively. Despite the better granularity, the 83-strip WLS geometry exhibited poorer resolution due to fewer photons being transmitted to the strip, resulting in large fluctuations of signal.

31-12-2023 - Brief communication
Oleg Bezshyyko, Larysa Golinka-Bezshyyko

In this article, we present the modern state of development of boron neutron capture therapy (BNCT) for cancer treatment using compact neutron generators. In the introduction we consider the main advantages and problems of the BNCT method, the main approaches and directions for building neutron sources, the development of chemical materials – boron-containing delivery agents and the control of irradiation of malignant tumours and healthy tissues. In the main part of the article we consider the main structures of neutron generators that can be effective for applying in BNCT. The development and building of a prototype of a compact neutron generator is also described.

31-12-2023 - Original article
Faranak Tayefi Ardebili, Szymon Niedźwiecki, Paweł Moskal

The Modular J-PET represents the latest advancement in the Jagiellonian-PET series, utilizing extended plastic scintillator strips. This prototype's modular design enables cost-effective imaging of multi-photon annihilation and positronium, allowing for easy assembly, portability, and versatility. Additionally, its lightweight construction facilitates static bed examinations with a mobile detection system that can be positioned conveniently alongside the patient, negating the requirement for spacious clinical settings. Comprising 24 modules arranged in regular 24-sided polygons circumscribing a 73.9 cm diameter circle, each module integrates 13 scintillator strips, measuring 50 cm in length and 6 mm × 24 mm in cross-section. Scintillation light is captured at both ends through analog Silicon Photomultipliers (SiPMs). This research presents Sensitivity of the Modular J-PET tomograph, adhering to the NEMA_NU 2-2018 standards. Sensitivity measurement was performed with 68Ge line source inside the 5 sleeves aluminium phantom placed at center of the detector`s field-of-view (FOV) and 10 cm offset from the center of detector. Analyzing the gathered data involved employing the specialized J-PET Framework software, developed within the C++ architecture. To validate the experimental findings, comparisons were made with GATE simulations, wherein the source and phantom were emulated in the same configuration as employed in the actual experiment. The system sensitivity of the Modular J-PET was assessed to be 1.03 ± 0.02 cps/kBq in the center of the detector`s FOV with the peak sensitivity of 2.1 cps/kBq. However, the simulations indicate that at the center of the detector's FOV, the Modular J-PET achieves a system sensitivity of 1.32 ± 0.03 cps/kBq, with a peak sensitivity of 2.9 cps/kBq.

31-12-2023 - Original article
Ihor Kadenko, Nadiia V. Sakhno, Pawel Moskal

Dose delivery in proton beam therapy requires significant effort for in vivo verification. PET is considered as one of the most precise methods for such verification using short-lived radionuclides. One of the newer approaches in proton therapy is based on FLASH therapy, when a 40–60 Gy absorbed dose could be delivered in millisecond time intervals. For this very promising type of therapy a very important task is to reliably identify the beam stopping position within the corresponding organ with a tumor in the patient’s body. This could be done if the beam proton energy in the body is still above the threshold of the corresponding nuclear reaction, in the outgoing channel of which will be produced positron-emitting nuclei. In this work we consider the production of oxygen radionuclides emitting positrons 14O (the half-life 70.6 s) and 15O (the half-life 122.2 s). Using the TALYS code, we calculated cross sections of proton-induced nuclear reactions on 14N and 16O, leading to the formation of 14,15O with the application of a well-working optical model. In addition, we calculated total gamma-production and average gamma-emission energy for incident proton energy 150 MeV.

 
31-12-2023-Original article - Pages: 132 - 138

Evaluation of Modular J-PET sensitivity

  • 1. M. Smoluchowski Institute of Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University; Total-Body Jagiellonian-PET Laboratory, Jagiellonian University; Theranostics Center, Jagiellonian University, Krakow, Poland
  • 2. M. Smoluchowski Institute of Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University; Total-Body Jagiellonian-PET Laboratory, Jagiellonian University; Theranostics Center, Jagiellonian University, Kraków, Poland
Published:31-12-2023

Language versions:
114
2624
DOI:10.5604/01.3001.0054.1973
GICID:01.3001.0054.1973


 

Abstract

The Modular J-PET represents the latest advancement in the Jagiellonian-PET series, utilizing extended plastic scintillator strips. This prototype's modular design enables cost-effective imaging of multi-photon annihilation and positronium, allowing for easy assembly, portability, and versatility. Additionally, its lightweight construction facilitates static bed examinations with a mobile detection system that can be positioned conveniently alongside the patient, negating the requirement for spacious clinical settings. Comprising 24 modules arranged in regular 24-sided polygons circumscribing a 73.9 cm diameter circle, each module integrates 13 scintillator strips, measuring 50 cm in length and 6 mm × 24 mm in cross-section. Scintillation light is captured at both ends through analog Silicon Photomultipliers (SiPMs). This research presents Sensitivity of the Modular J-PET tomograph, adhering to the NEMA_NU 2-2018 standards. Sensitivity measurement was performed with 68Ge line source inside the 5 sleeves aluminium phantom placed at center of the detector`s field-of-view (FOV) and 10 cm offset from the center of detector. Analyzing the gathered data involved employing the specialized J-PET Framework software, developed within the C++ architecture. To validate the experimental findings, comparisons were made with GATE simulations, wherein the source and phantom were emulated in the same configuration as employed in the actual experiment. The system sensitivity of the Modular J-PET was assessed to be 1.03 ± 0.02 cps/kBq in the center of the detector`s FOV with the peak sensitivity of 2.1 cps/kBq. However, the simulations indicate that at the center of the detector's FOV, the Modular J-PET achieves a system sensitivity of 1.32 ± 0.03 cps/kBq, with a peak sensitivity of 2.9 cps/kBq.

 

INTRODUCTION

Positron Emission Tomography (PET) is the most advanced molecular imaging method for assessing disease activity at the molecular and cellular levels [1]. The concept of PET dates back to the 1950s, and the first tomographs with clinical uses were produced in the 1970s. Since then, many technological advancements have enabled a constant search for improved systems [2–4]. The J-PET Collaboration has developed a novel prototype PET system at Jagiellonian University in Krakow, Poland, which is cost-effective and enables multi-photon and positronium imaging [5–11]. Its innovation arises from applying plastic scintillators instead of inorganic crystals used in classical PET scanners [7, 12, 13].

J-PET scanner may constitute an economical alternative for crystal PET scanners since plastic scintillators are more than an order of magnitude cheaper than crystals. In addition, the utilization of plastic PET with axially arranged scintillator strips decreases significantly costs of readout electronics and SiPMs for the J-PET scanner, which are expected to be about five times less than the current crystal- -based PET tomograph [14]. However, the efficiency of plastic scintillators is rather low. The linear attenuation coefficient for the 511 keV photons for the plastic scintillator is much lower than the crystal scintillator (0.096 1/cm for plastic scintillator with respect to 0. 83 1/cm for LYSO) [15]. This implies that in a single scintillator layer with a typical thickness of PET scan (2–3 cm) [2], in the case of crystal scintillator, most of the annihilation photons hitting the detector are detected, but in the case of plastic scintillators only about a quarter (17–25%) of annihilation photons are detected with the detector [2, 6, 15]. Although plastic scintillators exhibit a lower efficiency compared to crystals, this limitation can potentially be mitigated through the utilization of a multi-layer geometry approach employing axially arranged strips [6]. The significantly lower light attenuation in plastic with respect to crystals enables the effective light transport in long strips [16–18]. Another disadvantage of plastic scintillators is the negligible fraction of the photo-electric effect for the interaction of 511 keV photons. However, it does not preclude the possibility of the scatter fraction reduction; because in the plastic scintillators, the detection of 511 keV gamma quanta is based in practice only on the Compton scattering, and the by setting the threshold on energy deposition on 200 keV [7] a scatter fraction can be reduced below 40% [18].

The Modular J-PET scanner employed in this study is the latest generation of J-PET scanners developed by J-PET collaboration, as depicted in Fig. 1. Modular J-PET utilizes unique detection principles thanks to its novel detector arrangements [10–14]. Application of the triggerless data acquisition system [19], enables the execution of multi-photon and positronium imaging. The construction of Modular J-PET from plastic scintillator, alongside its unique detection principles, facilitates the acquisition of 50 cm of the AFOV [20–24]. The National Electrical Manufacturers Association (NEMA), the association of medical imaging and electrical equipment manufacturers in the United States, publishes medical diagnostic imaging equipment standards. One of its standards is NEMA-NU-2, which pertains to PET scanners [25]. The objective of this article is to assess the sensitivity of the Modular J-PET scanner in alignment with the NEMA-NU2_2018 standards. The empirical findings obtained were cross-validated using Monte Carlo simulations facilitated by GATE software. Future work will present all characteristics of Modular J-PET based on the experimental data and simulation.

Alternate image: Fig. 1. (A) Illustrates the Modular J-PET detector, comprising 24 modules. Eac ...

Fig. 1. (A) Illustrates the Modular J-PET detector, comprising 24 modules. Each module consists of 13 scintillator strips, with readout facilitated by a 1 × 4 SiPM array on both ends. These modules allow convenient removal for maintenance purposes, with a total weight of approximately 2 kg. Analog signals undergo digitization in close proximity to the SiPMs via specialized TDC boards developed by the J-PET group; (B) Depicts the power supply board (green), responsible for supplying voltage individually to each SiPM. Additionally, the TDC board (blue) performs the conversion of analog signals to digital format, retaining information regarding signal crossings at two preselected constant thresholds [22].

 

METHOD AND MATERIALS

Design of the Modular J-PET

The Modular J-PET scanner comprises 24 detection modules, each composed of 13 BC-404 rectangular plastic scintillator strips measuring 24 mm x 6 mm x 500 mm. These strips are arranged axially, forming a symmetrical 24-sided polygon that encloses the scanner. This configuration provides an AFOV spanning a total of 50 cm, with a scanner diameter measuring 73.9 cm as depicted in Fig. 1. [21, 23]. In order to enhance the propagation of light and ensure impermeability to light leakage, plastic scintillator strips are enveloped using a combination of Vikuiti Enhanced Specular Reflector (ESR) foil and DuPont Kapton 100B film [26–28]. Each plastic scintillator is read out on both ends by 4 Hamamatsu-S13 Silicon Photomultipliers (SiPMs) with an area of 6 x 6 mm2. When a gamma quanta interacts within a scintillator strip, four timestamps are generated – two at the leading edge and two at the trailing edge – across the eight SiPMs. These timestamps, captured by the front-end electronics, are continuously collected by the Data Acquisition System (DAQ). The functionality of the J-PET DAQ System is rooted in its Field-Programmable Gate Array (FPGA) electronics, enabling the efficient real-time processing of multiple data streams through pipelined operations [29].

Determination of the Modular J-PET sensitivity

The sensitivity of a PET scanner is defined as the number of counts per unit of time detected by the detector for each unit of activity present in a source [25]. The sensitivity of a PET scanner is expressed as a true coincidence events rate (cps/kBq). Sensitivity assessments were performed utilizing a 70 cm sensitivity phantom, located at the centre of detectors FOV and a 10 cm offset from the center of detector’s FOV. The sensitivity phantom is composed of 5 aluminium sleeves, with the 2.5 mm thickness and different diameters (as listed in Tab. I.), to minimize the effect of attenuation. The sensitivity measurements were carried out utilizing a 70 cm 68Ge line source with an activity level of 2.6 MBq for 6 hours. Separate measurements were performed through adding one layer of aluminium at each step. The choice of a 6-hour duration alongside of 2.6 MBq activity of the line source meet NEMA_NU2-2018 standards criterion, which recommend collecting data for a period ensuring the acquisition of at least 10,000 trues per slice. The total system sensitivity represents its capability to detect gamma photons emitted from positron annihilation events within the patient’s body and was conducted using the following formula:

undefined

where, R0 stand for the unattenuated count rate and, Anorm stand for normalized activity. To account for uncertainties, the error propagation principle was applied in the determination of

undefined

Normalization of the source's activity within the detector was necessary due to differing lengths of the AFOV detector and the line source, determined as follows:

undefined

where, Acal denotes the corrected initial activity. Subsequent analysis relied on normalized activity value of 1.8 MBq. The axial sensitivity profile is derived by plotting the sensitivity for individual slices, utilizing measurements obtained with the smallest tube (R1) placed at the centre of the detectors FOV.

Event selection criteria

The collected data underwent analysis using a dedicated C++ language-based framework [12, 30]. Within the dataset, interactions resulting from a single positron-electron annihilation and all subsequent interactions of secondary particles formed a sequence of consecutive photon interactions, constituting a single event. Coincidence events arose from any two scatterings within an event, provided their interaction times fell within a 4 ns time window. Detected coincidence events were categorized into three types: true coincidences, scatter coincidences, and accidental (or random) coincidences [13]. Fig. 2. present different type of coincidence event, that in both scatter and accidental coincidence events, the annihilation event didn’t align with the apparent line of response between the two-photon detections. Such scattered and random coincidences contributed to background noise, thereby diminishing image quality. To reduce background coincidence events, the initial data selection phase involved removing all events with one, three, or more hits, while retaining only those events that exhibited precisely two hits within the 4 ns coincidence time window.

Alternate image: Tab. I. Sensitivity measurement phantom details. ...

Tab. I. Sensitivity measurement phantom details.

The number of SiPMs connected to a single scintillator which give the signal was defined as multiplicity cut. A multiplicity cut equal to 8 SiPM signals is expected in the ideal case. Multiplicity cut was the subsequent stage of the data selection.

Further data refinement involved assessing the hit distribution origin based on the estimated energy deposition in a scintillator strip, derived from the time-over-threshold (TOT) values using the relation established in reference [31]. Fig. 3. illustrates the histogram of the sum of TOT values from two thresholds (30 mV and 70 mV) from both sides of each scintillator in the Modular J-PET prototype. Subsequently, a TOT range spanning from 2824 ns.mV to 4801 ns.mV was applied for future analyses. Moreover, limitations were imposed on the FOV of the Modular J-PET in the x and y directions, confined within a circle with a radius of 30 cm. Additionally, the z-coordinate of the annihilation position was restricted within a range of ± 25 cm, rejecting all events with larger z-coordinate values.

The residual background was suppressed using the scatter test (ST) criterion. For hits assigned to annihilation photons (ti, ri) and (tj, rj), the ST was defined as the difference between the measured times (Δt = |tj – ti|) and the time the photon would require to travel from rj to ri (ST = δi,j = di,j − c·|Δti,j|, where di,j is the distance between the i-th and j-th recorded interactions, and Δti,j is the difference in their recording times) as display in Fig. 3. Events with δi,j > 40 cm were selected, reducing a substantial fraction of accidental coincidences spread across the entire ST range.

Alternate image: Fig. 2. (A) Illustrates the schematic definitions of different types of coinci ...

Fig. 2. (A) Illustrates the schematic definitions of different types of coincidences: (a) true coincidence; (B) random coincidence; (C) detector-scattered coincidence, and (D) phantom-scattered coincidence. Central circle represents the patient, while the red detectors signify specific interactions of gamma quanta within the detectors. In background coincidence events, the annihilation event (indicated with e+,e-) doesn't correspond to the anticipated line of response between the two detected photons.

Alternate image: Fig. 3. (Left) Representative histogram showcasing the total time-over-thresho ...

Fig. 3. (Left) Representative histogram showcasing the total time-over-threshold (TOT) for all scintillators, employed in photon identification. The TOT distribution corresponds to a 5 sleeves sensitivity phantom positioned at the center of the detector's FOV. Applied cuts are denoted by red dotted lines, (Right) Visualisation depicting the scatter test (δi,j = di,j – c·|Δti,j|) applied to all events involving a 5-sleeve sensitivity phantom located at the center of the detector's field of view. Secondary scattering interactions manifest with themselves small δi,j values and are therefore excluded from further analysis. Interactions exceeding a δi,j value of 40 cm are identified as primary photon candidates.

Monte Carlo modelling of the Modular J-PET

The Modular J-PET simulation has been carried out with the use of the Geant4 Application for Tomographic Emission (GATE) software (version 9.0) [32–36] based on the Geant4 toolkit (version 10-06) [37], which is used to simulate the interaction of these photons in the detector material. Simulations were performed using the list of physics processes emlivermore_polar. The model represents the interactions of photons and electrons with matter down to 10 eV and up to 100 GeV [38]. This range of energy suits well the region of interest in PET tomography. In simulation, just the material properties of the BC-404 scintillator (1.021.0606 g ∙ cm−3) [39] were simulated.

For the computation of the scanner’s sensitivity, a simulation involving a 70 cm linear 2.6 MBq source of 68Ge was conducted within the sensitivity phantom. This simulation was repeated while reducing the number of aluminium tubes from 5 to 1. Each simulation iteration involved positioning the source and phantom at two distinct locations: the central point of the FOV and an offset of 10 cm from the tomograph center, as depicted in Fig. 4. Simulations were performed, assuming the detection chamber, phantom, and source were placed in the air. To mitigate the influence of events involving photon scatter within the detector and phantom, simulated events underwent filtration based on specific criteria derived from correlations between the gamma quanta’s time of interaction with the scintillator (hit time) and the energy transferred by the gamma quanta to electrons within the material (energy deposition) [33].

Alternate image: Fig. 4. (A) GATE visualisation of the Modular J-PET with sensitivity phantom l ...

Fig. 4. (A) GATE visualisation of the Modular J-PET with sensitivity phantom located in the center of the FOV; (B) Side view of the Modular J-PET with the sensitivity phantom in the centre of the detectors FOV; (C) Cross section of Module J-PET, two red point present the position of sensitivity phantom inside the detector’s FOV; (D) GATE visualisation of one module of Modular J-PET. The plastic scintillator strips are depicted in gray, while the SiPMs on both sides of the module are displayed in black; (E) GATE visualization of sensitivity Phantom with five sleeve tubes displayed with red and one polyethylene tube with length of 70 cm displayed with gray, also illustration of sensitivity phantom cross section. each sleeves has 2.5 mm thickness with different diameter according to NEMA-NU2_2018. The figure isn’t to scale.

Alternate image: Fig. 5. Axial sensitivity profile for the smallest sleeve in the center of det ...

Fig. 5. Axial sensitivity profile for the smallest sleeve in the center of detector’s FOV for experimental data and simulation data. Experimental data studied under different multiplicity cuts. The red line depicts the axial sensitivity profile at the center of the detector derived from simulation data. The peak point in the axial sensitivity profile defined as peak sensitivity and is equal to 2.9 cps/kBq for simulation data while the total system sensitivity is 1.32 ± 0.03 cps/kBq. In the experimental data for multiplicity cuts greater than or equal to 5, the peak sensitivity is 2.1 cps/kBq while the total system sensitivity is 1.03 ± 0.02 cps/kBq.

Therefore, to extract true coincidences from the set of all coincidences, true coincidence events were defined, such as only events with two interactions registered with an energy loss larger than the fixed energy threshold of (200 keV). Moreover, it is required that Time of flight (TOF) is less than 3 ns. The study incorporated experimental resolutions in the dataset, encompassing a time resolution (FWHM) of 628 ps and an energy resolution of 0.23% at 340 keV. The dead time of 20 ns also applied to simulation. Furthermore, to suppress additional scattering coincidences during analysis, the scatter test cuts (ST > 40 cm) and geometry cut (x2 + y2 ≥ 302, |Z| ≥ 25 cm) were applied to simulation data.

 

RESULTS

The determination of total sensitivity for both experimental and simulation data was accomplished using Equation 1 at specific positions. Tab. II. presents the total system sensitivities alongside their comparative analysis with simulation results.

Since the sensitivity is strongly dependent on the count rate after the application of all data selection criteria, altering the multiplicity criterion (Number of SiPMs connected to both ends of each detector module) distinctly affects both the axial sensitivity profile and the overall system sensitivity. The sensitivity of the Modular J-PET system across different multiplicity cuts (= 8, ≥7, ≥6, ≥5) at the center of detector’s FOV was investigated. Fig. 5. illustrates the axial sensitivity profile for experimental data under various multiplicity cuts, with simulation results for a 1-sleeve phantom positioned at the center of detector’s FOV. These simulated axial sensitivity profiles are in good agreement with experimental data employing a multiplicity cut of greater than or equal to 5. The peak sensitivity profile for experimental data with a multiplicity cut of ≥5 registered at 2.1 cps/kBq, while simulation results indicate 2.9 cps/kBq at the center of detector’s FOV. These relatively minor differences were expected due to not modelled some electronic and digitizer parameters. Furthermore, the definition of detector-scattered coincidence events in the GATE software contributes to these differences.

 

DISCUSSION

The objectives of this work were to estimate and analyze the Sensitivity of the Modular J-PET system using the NEMA_NU2_2018 guidelines for system evaluation. NEMA norm requires estimations of sensitivity using 70 cm long linear source and the sensitivity phantom of the same length at two positions: centre of the detector`s FOV and 10 cm offset from the centre of the detectors FOV. To validate the experimental results, a Monte Carlo model of the Modular J-PET scanner was employed through the GATE simulation platform. The results obtained from simulations conducted on the 70 cm phantom exhibited concordance with the experimental measurements carried out on the Modular J-PET scanner.

Alternate image: Tab. II. Comparison of the total system sensitivity and peak sensitivity profi ...

Tab. II. Comparison of the total system sensitivity and peak sensitivity profile for the simulation and experimental data at the center of detector's FOV and at 10 cm offset from the center of the detector's FOV.

The sensitivity of a PET scanner depends on the system’s geometric acceptance, detection efficiency, and dead time. It means that the sensitivity depends on the scintillation decay time, density, atomic number, thickness of the detector material, the distance between the source and the detector, the diameter of the ring, and the number of detectors in the ring. For this reason, PET scanners made of LSO or BGO scintillators are more sensitive [40–43]. However, PET scans from plastic scintillators are economical. On the other hand, Large axial field of view scanner sensitivity increases significantly with axial length. The axial arrangement of detectors and utilized technology in the J-PET scanner leads to increased AFOV in the J-PET detector, just by extending the plastic scintillator length. Because the main geometrical difference between the J-PET tomograph and other PET scanners is the arrangement of scintillators and photodetectors. Also, increasing the distance between the detector and the source reduces the solid angle and thus decreases the geometric efficiency of the scanner and vice versa. Yet, the sensitivity of Modular J-PET may be further increased by adding a second detection layer or extending the AFOV [6]. The sensitivity of J-PET and crystal PET based scanners is evaluated and compared in the reference [40]. The aim of the study Modular J-PET scanner with a 50 cm long AFOV provided a an intermediate result for the development of cost-efficient Total-Body PET which is able to cover all of the patient’s body [14].

 

CONCLUSIONS

The sensitivity profiles for the Modular J-PET scanner were assessed across various multiplicity cuts, revealing an increase in sensitivity as the multiplicity number decreases. This trend leads to comparable outcomes with simulations, notably for a multiplicity greater than or equal to 5. This congruence arises from the absence of optical photon simulations during the simulation phase. Specifically, the peak sensitivity profiles for experimental data, employing multiplicity cuts of greater than or equal to 5, and simulation data stand at 2.1 cps/kBq and 2.9 cps/kBq, respectively, at the detector’s center. While the total system sensitivity in the centre of the detector`s FOV for experimental data, employing multiplicity cuts of greater than or equal to 5 is 1.03 ± 0.02 cps/kBq, and for simulation results, it is 1.32 ± 0.03 cps/kBq. Extending the length of the plastic scintillator strips and implementing a multi-layer PET scan are anticipated strategies to enhance the sensitivity of the Modular J-PET.

 

ACKNOWLEDGEMENTS

We acknowledge support from the Foundation for Polish Science through the TEAM POIR.04.04.00-00-4204/17 program, the National Science Centre of Poland through Grants No. 2021/42/A/ST2/00423, 2021/43/B/ST2/02150, 2019/35/B/ST2/03562, Jagiellonian University via Project No. CRP/0641.221.2020, and the SciMat and qLife Priority Research Area budget under the auspices of the program Excellence Initiative – Research University at Jagiellonian University.

 

CONFLICT OF INTEREST

Authors have declared no potential conflicts of interest.

References:

1.
Alavi A, Werner T, Stepien E, Moskal P. Unparalleled and revolutionaryimpact of PET imaging on research and day to day practice of medicine.Bio-Algorithms and Med-Systems. 2021;17:203-12.
2.
Vandenberghe S, Moskal P, Karp JS. State of the art in total body PET.EJNMMI Phys. 2020;7:35.
3.
Surti S, Pantel AR, Karp JS. Total Body PET: Why, How, What for?. IEEETrans Radiat Plasma Med Sci. 2020;4(3):283-92.
4.
Alavi A, Saboury B, Nardo L, Zhang V, Wang M, Li H, et al. Potentialand most relevant applications of total body PET/CT imaging. Clin NuclMed. 2022;47:43-55.
5.
Moskal P, Dulski K, Chug N, Curceanu C, Czerwiński E, Dadgar M, etal. Positronium imaging with the novel multi-photon PET scanner. SciAdv. 2021;7:eabh4394.
6.
Moskal P, Kowalski P, Shopa RY, Raczyński L, Baran J, Chug N, et al. SimulatingNEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators. Phys MedBiol. 2021;66:175015.
7.
Moskal P, Niedźwiecki S, Bednarski T, Czerwiński E, Kapłon Ł, KubiczE, et al. Test of a single module of the J-PET scanner based on plasticscintillators. Nucl Instrum Methods Phys Res A. 2014;764:317-28.
8.
Moskal P, Zoń N, Bednarski T, Białas P, Czerwiński E, Gajos A, et al. Anovel method for the line-of-response and time-of-flight reconstructionin TOF-PET detectors based on a library of synchronised model signals.Nucl Instrum Methods Phys Res A. 2015;775:54-80.
9.
Niedźwiecki S, Białas P, Curceanu C, Czerwiński E, Dulski K, Gajos A.et al. J-PET: a new technology for the whole-body PET imaging. ActaPhys Polon B. 2017;48:1567-70.
10.
Moskal P, Kisielewska D, Curceanu C, Czerwiński E, Dulski K, Gajos A,et al. Feasibility study of the positronium imaging with the J-PET tomograph.Phys Med Biol. 2019;64:055017.
11.
Moskal P, Jasińska B, Stępień E, Bass SD. Positronium in Medicine andBiology. Nat. Rev. Phys. 2019;1(9):527-9.
12.
Krzemien W, Alfs D, Białas P, Czerwiński E, Gajos A, et al. Overview ofthe software architecture and data flow for the J-PET tomography device.Acta Phys Polon B. 2016;47:561.
13.
Kowalski P, Wiślicki W, Raczyński L, Alfs D, Bednarski T, Białas P, GłowaczB, et al. Scatter fraction of the J-PET tomography scanner. ActaPhys Polon B. 2016;47:549.
14.
Moskal P, Stepien E. Prospects and clinical perspectives of total-bodyPET imaging using plastic scintillator. PET Clinics. 2020;15(4):439-52.
15.
National Institute of Standards and Technology, 2020 [cited 2023 Dec 11]. Available from: https://nist.gov/pml.
16.
Crystal [cited 2023 Dec 11]. Available from: https://www.crystals.saint-gobain.com/.
17.
Vilardi I, Braem A, Chesi E, Ciocia F, Colonna N, Corsi F, et al. Optimizationof the effective light attenuation length of YAP:Ce and LYSO:Cecrystals for a novel geometrical PET concept. Nucl Instrum MethodsPhys Res. 2006;564:506-14.
18.
Mao R, Zhang L, Zhu RY. Optical and Scintillation Properties of InorganicScintillators in High Energy Physics. IEEE Trans. Nucl. Sci.2008;55:2425-31.
19.
Korcyl G, Bialas P, Curceanu C, Czerwiński E, Dulski K, Flak B, et al. Evaluationof Single-Chip, Real-Time Tomographic Data Processing on FPGASoC Devices. IEEE Trans. Med. Imaging. 2018;37(11).
20.
Dadgar M, Parzych S, Tayefi Ardebili F. A Simulation Study to EstimateOptimum LOR Angular Acceptance for the Image Reconstruction withthe Total-Body J-PET. Med Image Anal. 2021;12:189-200.
21.
Dadgar M, Kowalski P. GATE Simulation Study of the 24-Module JPETScanner: Data Analysis and Image Reconstruction. Acta Phys. Pol. B2020;51:309-11.
22.
Palka M, Strzempek P, Korcyl G, Bednarski T, Niedźwiecki S, Białas P, etal. Multichannel FPGA based MVT system for high precision time (20 psRMS) and charge measurement. J. Instrum. 2017;12:08.
23.
Kapłon L, Moskal G. Blue-emitting polystyrene scintillators for plastic scintillationdosimetry. Bio-Algorithms and Med-Systems. 2021;17(3):191-7.
24.
Moskal P, Bednarski T, Niedzwiecki S, Silarski M, Czerwinski E, KozikT, et al. Synchronization and Calibration of the 24-Modules J-PET PrototypeWith 300-mm Axial Field of View. IEEE Trans Instrum Meas.2021;70:1-10.
25.
NEMA Standards Publication NU 2-2018: Performance Measurementsof Positron Emission Tomographs. National Electrical Manufacturers Association.Rosslyn VA, USA, 2018.
26.
3M [cited 2021 Mar 24]. Available from: https://www.3m.com.
27.
Dupont [cited 2021 Mar 24]. Available from: https://www.dupont.com.
28.
Kaplon L. Technical Attenuation Length Measurement of Plastic ScintillatorStrips for the Total-Body J-PET Scanner. IEEE Trans. Nucl. Sci.2020; 67(10): 2286-9.
29.
Korcyl G, Białas P, Curceanu C, Czerwiński E, Dulski K, Flak B, et al. Evalationof single-chip, real-time tomographic data processing on fpga socdevices. IEEE Trans. Med. Imaging. 2018;37:2526-35.
30.
Krzemien W, Gajos A, Kacprzak K, Rakoczy K, Korcyl G. J-pet framework:Software platform for pet tomography data reconstruction andanalysis. SoftwareX. 2020;11:100487.
31.
Sharma S, Chhokar J, Curceanu C, Czerwiński E, Dadgar M, Dulski K, etal. Estimating relationship between the Time Over Threshold and energyloss by photons in plastic scintillators used in the J-PET scanner.EJNMMI Phys. 2020;7:39.
32.
Jan S, Santin G, Strul D, Staelens S, Assié K, Autret D, et al. GATE - Geant4Application for Tomographic Emission: a simulation toolkit for PETand SPECT. Phys Med Biol. 2004; 49(19):4543–61.
33.
Jan S, Benoit D, Becheva E, Carlier T, Cassol F, Descourt P, et al. GATEV6: a major enhancement of the GATE simulation platform enabling modellingof CT and radiotherapy. Phys Med Biol. 2011;56(4):881.
34.
Sarrut D, Bała M, Bardies M, Bert J, Chauvin M, Chatzipapas K, et al. AdvancedMonte Carlo simulations of emission tomography imaging systemswith GATE. Phys Med Biol. 2021; 66(10):10TR03.
35.
Agostinelli S, Allison J, Amako K, Apostolakis J, Araujo H, Arce P, et al.Geant4—a simulation toolkit. Nucl Instrum Methods Phys Res A: AccelSpectrom Detect Assoc Equip. 2003;506:250.
36.
Kowalski P, Raczyński L, Bednarski T, Białas P, Czerwiński E, Giergiel K,et al. Determination of the map of efficiency of the Jagiellonian PositronEmission Tomograph (J-PET) detector with the GATE package. Bio-Algorithmsand Med-Systems. 2014;10(2):85-90.
37.
Allison J, Amako K, Apostolakis J, Arce P, Asai M, Aso T, et al. Recentdevelopments in GEANT4. Nucl Instrum Methods Phys Res A: AccelSpectrom Detect Assoc Equip. 2016;835:186.
38.
Kowalski P, Moskal P, Wislicki W, Raczynski L, Bednarski T, BialasP, et al. Multiple scat tering and accidental coincidences in theJ-PET detector simulated using GATE package. Acta Phys Pol A.2015;127:1505-12.
39.
Eljentechnology [cited 2021 Mar 24]. Available from: https://eljentechnology.com/images/technical\_library/Physical-Constants-Plastic.pdf.
40.
Dadgar M, Parzych S, Baran J, Chug N, Curceanu C, Czerwiński E, et al.Comparative studies of the sensitivities of sparse and full geometriesof Total-Body PET scanners built from crystals and plastic scintillators.EJNMMI Phys. 2023; 10(62).
41.
Spencer B, Berg E, Schmall JP, Omidvari N, Leung EK, Abdelhafez YG, etal. Performance evaluation of the uExplorer total-body pet/ct scannerbased on NEMA-nu 2-2018 with additional tests to characterize petscanners with a long axial field of view. J Nucl Med. 2021;61:861.
42.
Karp J, Viswanath V, Geagan MJ, Muehllehner G, Pantel AR, Parma MJ,et al. PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager. J Nucl Med. 2020;61(1):136-43.
43.
Prenosil G, Sari H, Fürstner M, Afshar-Oromieh A, Shi K, Rominger A, etal. Performance Characteristics of the Biograph Vision Quadra PET/CTSystem with a Long Axial Field of View Using the NEMA NU 2-2018Standard. J Nucl Med. 2022;63(3):476-84.