03-09-2024 - Original article
Irena Roterman-Konieczna, Leszek Konieczny, Katarzyna Stapor

Aim: The structure of a multi-drug efflux system (specifically the outer membrane part) is the focus of our analysis. The role of electrostatic interactions in the efflux process is well understood.
Methods: Our analysis is made possible by the application of the fuzzy oil drop model in its modified form (FOD-M).
Results: The distribution of hydrophobicity in the periplasmic and membrane domains plays a significant role in both stabilisation within the membrane and in tunnel formation, which facilitates the transport of antibiotics.
Conclusions: The analysis presented in this paper reveals the specificity of hydrophobicity distribution in relation to biological activity, as well as a possible mechanism for the folding process of proteins involved in multi-drug efflux.

03-09-2024 - Original article
Yavuz Selim Kıyak, Işıl İrem Budakoğlu, Özlem Coşkun

Aim: We aimed to reveal awareness of distributed ledger technologies (DLTs) among clinical year students (fourth, fifth, and sixth years in undergraduate medical training) in a medical school.
Methods: This was a descriptive study. The participants were clinical year medical students in a medical school. We developed an electronic survey form on blockchain, Holochain, and other DLTs. Self-perceived knowledge levels on DLTs and Web3 were solicited, as well as DLT-based cryptocurrency-related questions to understand their practical involvement. This approach was taken because, while DLTs are used in healthcare and education, their most common application is in cryptocurrencies. We reported descriptive statistics.
Results: Total number of participants was 546. Of the students, 74.7% have never heard of blockchain, and 86.3% have never heard of Holochain. DLTs such as DAG (Directed Acyclic Graph), Hashgraph, and Tempo have never been heard of by over 90% of the students. 75.3% stated they are worried about the security and privacy of their data on the internet. 20.3% of the students stated that they have purchased a cryptocurrency at least once, 7.9% used a cryptocurrency wallet where they hold its private key, and 6.8% used a decentralized exchange. If there were an elective course on DLTs in the faculty, 54.8% of the students would be willing to take this course.
Conclusions: DLT and Web3 awareness among medical students is low. However, there is an interest in taking an elective course on these technologies. In order to create awareness, medical schools could leverage this interest to learn more about Web3 solutions.

31-12-2024 - Erratum
Monika Szczepanek, Dominik Panek, Małgorzata Przybyło, Paweł Moskal, Ewa Ł. Stępień

When the article was first published in 2022, there were a few incorrect details and authors would like to submit the following corrections for the article:
(1) In the original version of this article the affiliation of Monika Szczepanek, who is the corresponding author, is incorrect.
On the page 144, the following sentence:
*Corresponding authors: Monika Szczepanek, Center for Theranostics, Jagiellonian University, Kopernika 40 St., 31-034 Krakw, Poland, e-mail: monika.szczepanek@doctoral.uj.edu.pl
should have read:
*Corresponding authors: Monika Szczepanek, Department of Medical Physics, M. Smoluchowski Institute of Physics, Jagiellonian University, Łojasiewicza 11 St., 30-348 Kraków, Poland; Center for Theranostics, Jagiellonian University, Kopernika 40 St., 31-034 Kraków, Poland
(2) In the original version of this article there is an error in the name of the 4F2hc gene in the Abstract and Results/Discussion sections. In these sections, the incorrect name „4Fhc” appears three times instead of the correct name.
On the page 144 (Abstract), the following sentence:
Results: Transcriptomic data show that in melanocytes, LFC for SLC7A5 (LAT1) and SLC3A2 (4Fhc) was higher than in melanoma cell lines, which corresponded with their melanin content.
should have read:
Results: Transcriptomic data show that in melanocytes, LFC for SLC7A5 (LAT1) and SLC3A2 (4F2hc) was higher than in melanoma cell lines, which corresponded with their melanin content.
On the pages 147-148 (Results/Discussion), the following sentences:
This is because this gene encodes a heavy chain (4Fhc) subunit necessary for the proper function of LAT1 [10]. This relationship was also evident for WM115 and WM266- 4 where we observed the highest expression levels of the SLC7A5 (LAT1) and SLC3A2 (4Fhc) genes.
should have read:
This is because this gene encodes a heavy chain (4F2hc) subunit necessary for the proper function of LAT1 [10]. This relationship was also evident for FM55p and WM266-4 where we observed the highest expression levels of the SLC7A5 (LAT1) and SLC3A2 (4F2hc) genes.
(3) In the original version of this article an error occurred while typing of the name of the HEMa-LP cell line. The incorrect name “HEMa-Lp” appears instead of the correct name in the article. This error has since been corrected throughout the text and in Figures.
(4) In the original version of this article high melanotic melanoma cell line have been subject to misnomer. The incorrect name “WM115” appears instead of the correct name “FM55p” in the article. This error has now been corrected throughout the text and in Figures, and this correction has not changed the description, interpretation or the original conclusions of the manuscript.
(5) In the corrected version of this article a new reference number 26 has been added with information on the FM55p melanoma cell line.
On the pages 147 (Results/Discussion), the following sentence:
HEMa-Lp is a cell line derived from donor normal skin melanocytes, while WM115 and WM266-4 are melanoma cell lines from one patient [26].
should have read:
HEMa-LP is a cell line derived from donor normal skin melanocytes, while FM55p is a primary melanoma cell line [26] and WM266-4 is a metastatic melanoma cell line [27].
(6) Due to the addition of a new reference item (number 26) in the corrected version of this article, the numbering of references 26-27 in the original version of this article has been changed. Now they have numbers from 27-30.
The original article has been corrected. The authors apologize for any inconvenience caused by these errors.

21-11-2024 - Review article
Tejaswi Mudadla, Gayatri Sharma, Apoorva Mishra, Shefali Gola

Objective: This review aims to provide a comprehensive overview of omics fields – including genomics, epigenomics, transcriptomics, proteomics, metabolomics, single- -cell multiomics, microbiomics, and radiomics – and to highlight the significance of integrating these datasets to tackle complex biological questions in systems biology and precision medicine.
Methods: The review analyzes current literature across various omics domains, focusing on their individual contributions to cellular functions and their integration challenges. It discusses successful integration examples and addresses issues like data heterogeneity across databases.
Results: Omics integration significantly enhances our understanding of biological systems, with each field offering unique insights. Despite challenges with data inconsistencies, successful cases show the potential of integrated omics in advancing personalized medicine, drug discovery, and disease research.
Conclusions: Advancing omics integration is essential for breakthroughs in personalized medicine and complex disease studies. Interdisciplinary collaboration will be crucial to overcoming data challenges and realizing the full potential of omics in biomedical advancements.

11-12-2024 - Original article
Anurag Jagetiya, Pankaj Dadhech

Objective: Breast cancer remains a leading cause of mortality among women worldwide. Early detection and accurate prognosis are crucial for improving patient outcomes. This study presents a novel approach that integrates feature elimination techniques with machine learning to enhance the accuracy of breast cancer prognosis. The approach addresses class imbalance in the dataset to improve sensitivity, particularly in minimizing false negatives. Additionally, it emphasizes the use of machine learning algorithms, which are considered more transparent and computationally efficient compared to deep learning methods.
Method: The Wisconsin Breast Cancer (WBC) dataset was used to develop an interpretable machine learning model. Recursive Feature Elimination (RFE) identified key features, while Principal Component Analysis (PCA) reduced dimensionality. The optimized feature set was trained using XGBoost. To address class imbalance, class weighting and decision threshold adjustments were applied to improve sensitivity and minimize false negatives
Results: The model achieved high performance: accuracy of 99.12%, precision of 100%, recall of 97.69%, and an F1 score of 98.9%. Feature selection and class imbalance handling enhanced sensitivity and computational efficiency. The model's interpretable results highlight its suitability for clinical applications.
Conclusions: This study presents an interpretable machine learning model integrating RFE, PCA, and XGBoost to enhance breast cancer prognosis. High accuracy and sensitivity, coupled with explainability, make it a promising tool for clinical decisionmaking in early detection and treatment planning.

02-12-2024 - Case study
Patrycja Szymczyk-Ziółkowska, Małgorzata Rusińska, Grzegorz Ziółkowski, Karol Kobiela, Kinga Sekuła, Dawid Kęszycki, Anna Miner-Kordasiewicz

Objective: Maxillofacial injuries often necessitate complex reconstructive surgeries, requiring the design and fabrication of patient-specific implants (PSIs) to restore functionality and aesthetics. A 32-year-old male patient, who sustained a mandible injury, served as a case study.
Methods: This study presents advancements in maxillofacial reconstruction through the application of Electron Beam Powder Bed Fusion (PBF-EB/M), an additive manufacturing (AM) technique, in the creation of personalized jaw implants. CT scans were processed to develop a 3-D model of the patient's tissues, and Finite Element Analysis (FEA) was employed to assess mechanical behaviour.
Results: The PSI, manufactured from a Ti6Al4V ELI alloy, exhibited suitable mechanical properties and biocompatibility. This work presents a workflow that clarifies the principles of designing, verifying and manufacturing PSIs for maxillofacial reconstruction.
Conclusions: By integrating advanced imaging techniques, FEA simulations, and AM technologies, along with post-processing using CAM tools, the feasibility of producing personalized medical devices with modern manufacturing methods that offer enhanced design flexibility can be assessed. This includes highlighting both the potential benefits and challenges of the proposed approach.

18-12-2024 - Review article
Monika Weronika Piwowar, Magdalena Ptak-Kaczor, Jacek Dygut

Objective: This paper contains an overview of information related to the origin of the SARS-CoV-2 virus, its characteristics, including mutational variability, and monitoring the virus's presence in the human population.
Methods: A review of medical and biological literature from the PubMed/MEDLINE databases from 1998 to 2024 was performed regarding research on SARS viruses, particularly SARS-CoV-2.
Results and conclusions: At the end of 2019, cases of a new virus were recorded in China, which within a few months, as a result of free population migration, was transferred to various regions in the world. In the first quarter of 2020, the World Health Organization announced the SARS-CoV-2 pandemic. In addition to the characteristics of coronaviruses, headed by the SARS-CoV-2 virus, this manuscript contains several threads to provoke discussion, especially concerning the ethical aspects of “gain of function” research, which make pathogens more contagious, dangerous and lethal to humans. Attention is also paid to the essence of reliable work and documentation of scientific work.

20-12-2024 - Original article
Barbara Kmiecik, Katarzyna Niemczyk, Agnieszka Adamczyk, Aleksander Błachut, Jerzy Detyna

Objective: This study aimed to develop a measurement system to investigate the mechanical behavior of materials under applied force. The system was designed to evaluate the relationship between displacement and applied force and to analyze material deformation.
Methods: The measurement system comprised two high-resolution cameras, a robotic arm, and programmed sensors, all mounted on a custom-designed support structure. The components were selected based on a thorough review of the literature and the specific requirements for material testing. During the experiments, the system induced controlled deflection in the central region of the specimen. Surface deformation was tracked using custom-developed software, which reconstructed a 3-D model of the material based on specific tracking points. The displacement data were then used to generate a force-displacement curve. Hysteresis fields were computed to further analyze the material’s mechanical response.
Results: The system successfully reconstructed accurate 3-D surface models of the specimens during mechanical deformation. Force-displacement curves generated from the measurements provided detailed insights into the mechanical properties of the materials. The analysis of the hysteresis fields revealed deviations from expected behavior, offering information on the material’s response to applied force.
Conclusions: The measurement system proved to be an effective tool for characterizing material behavior under applied force. Its ability to integrate precise hardware with custom software allowed for accurate 3-D modeling and reliable force-displacement analysis. The results demonstrated the system’s applicability in material research and quality control. Future work may focus on extending its capabilities to a broader range of materials and testing conditions.

23-12-2024 - Original article
Yavuz Selim Kıyak, Andrzej A. Kononowicz, Stanislaw Górski

Objective: This study has two main aims. (1) To generate multiple-choice questions (MCQs) using template-based automatic item generation (AIG) in Polish and to evaluate the appropriateness of these MCQs in terms of assessing clinical reasoning skills in medical education; (2) to present a method for using artificial intelligence (AI) to generate new item models based on existing models for template-based AIG in medical education.
Methods: This was a methodological study. For the first aim, we followed Gierl’s three-step template-based AIG method to generate MCQ items in Polish. The quality of the generated MCQs were evaluated by two experts using a structured form. For the second aim, we proposed a four-step process for using a parent template in English to transform it into new templates. We implemented this method in ChatGPT and Claude by using two medical MCQ item models.
Results: Both experts found the automatically generated Polish questions clear, clinically sound, and suitable for assessing clinical reasoning. Regarding the template transformation, our findings showed that ChatGPT and Claude are able to transform item models into new models.
Conclusions: We demonstrated the successful implementation of template-based AIG in Polish for generating case-based MCQs to assess clinical reasoning skills in medical education. We also presented an AI-based method to transform item models for enhancing diversity in template-based AIG. Future research should integrate AI-generated models into AIG, evaluate their exam performance, and explore their use in various fields.

27-12-2024 - Original article
Piotr Walecki, Julianna Dąbrowa, Paulina Więcławek, Klaudia Gogól, Klaudia Proniewska

Introduction: Three-dimensional (3D) technologies, including virtual reality (VR), augmented reality (AR), and mixed reality (MR), are transforming medical education by providing immersive learning experiences that may enhance spatial understanding, knowledge retention and practical skills. Despite promising benefits, these technologies also present unique challenges, including potential physical and mental health impacts, which remain underexplored.
Objective: This study aimed to evaluate and compare VR, AR, MR and traditional teaching methods in medical education. The objectives were to assess each method’s effectiveness in enhancing student engagement and comprehension, identify associated health challenges and determine the potential of 3D technologies as complements or alternatives to traditional educational methods.
Methods: Eighty-four medical students participated in a structured 20-hour course, interacting sequentially with VR, AR, MR and traditional teaching modalities. Students’ experiences were documented through post-course evaluations, which assessed aspects such as immersion, engagement and health-related impacts.
Results: The study revealed that VR, AR and MR offered significant advantages over traditional methods in areas such as spatial understanding (VR, 64.29%; AR/MR; 67.86%) and visualization of 3D anatomical structures (VR, 57.14%; AR/MR, 69.05%). However, VR was associated with a high prevalence of health issues, including cybersickness (71.43%) and spatial disorientation (75.00%), highlighting the physical and psychological challenges of full immersion. AR/MR presented fewer adverse effects, though eye strain (63.10%) and sensory overload (50.00%) remained concerns. Traditional methods were generally safer but less effective in promoting interactive engagement and spatial comprehension.
Conclusions: 3D technologies provide valuable enhancements to medical education but require careful integration alongside traditional methods to mitigate health-related challenges. VR, AR and MR are best suited as complementary tools rather than direct replacements, supporting a hybrid educational model that maximizes learning outcomes while managing the physical and psychological impacts associated with immersive technologies. Further research on standardized implementation practices is needed to optimize these tools for broader educational use.

27-12-2024 - Original article
Manish Das, Reimund Bayerlein, Sushil Sharma, Szymon Parzych, Szymon Niedźwiecki, Ramsey Badawi, Ermias Yitayew Beyene, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Kavya Valsan Eliyan, Bogusław Głowa, Alicja Hubalewska-Dydejczyk, Krzysztof Kacprzak, Tevfik Kaplanoglu, Kamila Kasperska, Grzegorz Korcyl, Aleksander Khreptak, Karol Kubat, Deepak Kumar, Edward Lisowski, Filip Lisowski, Justyna Mędrala-Sowa, Simbarashe Moyo, Wiktor Mryka, Marta Opalińska, Piyush Pandey, Martin Rädler, Magdalena Skurzok, Anna Sowa-Staszczak, Benjamin A. Spencer, Pooja Tanty, Keyvan Tayefi Ardebili, Anoop Kunimmal Venadan, Elena Perez del Rio, Ewa Stępień, Paweł Moskal

Objective: Positron emission tomography (PET) is a widely used medical imaging technique that allows for non-invasive imaging of metabolic processes. However, traditional PET scanners rely on costly inorganic scintillators that limit their accessibility, especially in light of emerging long axial field-of-view devices. The modular J-PET scanner, an innovative alternative, uses 50-cm-long plastic scintillator strips, offering a cost-effective and modular solution. In this study we develop and assess the PET data correction techniques required for quantitative image reconstruction.
Methods: We present methods for attenuation correction, random coincidence correction using the delayed time window (DTW) technique and scatter correction based on Monte Carlo simulations. Phantom studies using the NEMA IQ phantom were performed to qualitatively evaluate these corrections.
Results: The results demonstrate that our implemented corrections for attenuation and random and scattered coincidences successfully improve the uniformity of tracer distribution in homogenous volumes and significantly reduce undesired activity in cold regions. Despite limitations in sensitivity and axial resolution, the applied correction techniques effectively enhance image quality, providing promising results for future applications.
Conclusions: These findings highlight the potential of the modular J-PET system to offer affordable PET imaging and to pave the way for a total-body PET scanner based on plastic scintillators. Future work will focus on quantitative validation and the implementation of these corrections for human subject imaging.

27-12-2024 - Original article
Kriti Awasthi, Narendra Rathod, Magdalena Kostkiewicz, Ewa Stępień

Objectives: This study aims to develop an advanced and efficient deep learning-based approach for the detection and segmentation of cell nuclei in microscopic images. By exploiting the U-Net architecture, this research helps to overcome the limitations of traditionally followed computational methods, enhancing the precision and scalability of biomedical image analysis.
Methods: This research utilizes a deep learning model based on the U-Net architecture and is trained and evaluated for cell nuclei segmentation. The model was optimized by fine-tuning parameters, i.e., applying data augmentation techniques and employing performance metrics such as Intersection over Union (IoU) for evaluation. Comparisons were made with traditional segmentation techniques to assess improvements in accuracy, efficiency, and robustness.
Results: This U-Net model demonstrated superior performance in segmenting cell nuclei compared to conventional methods. The results showed increased segmentation accuracy, lowering manual efforts, and enhanced reproducibility across different imaging datasets. The model's high IoU values confirmed its effectiveness in accurately identifying cell nuclei boundaries, making it a reliable tool for automated biomedical image analysis.
Conclusions: The study highlights the effectiveness of the U-Net architecture in automated cell nuclei detection and segmentation, addressing challenges associated with manual analysis. Its scalability and adaptability extend its applicability beyond cell nuclei segmentation to other biomedical imaging tasks, offering significant potential for disease diagnosis, therapeutic development, and clinical decision-making. The findings reinforce the transformative impact of deep learning in biomedical research and healthcare applications.

27-12-2024 - Original article
Sahar Nosrati Shanjani, Emilia Majka, Monika Łyczko, Rafał Walczak, Agnieszka Majkowska-Pilip, Aleksander Bilewicz

Objectives: The HER2 receptor is often overexpressed in various cancers, particularly in breast and ovarian cancers, and this overexpression significantly contributes to the growth and spread of these tumors. Trastuzumab (Herceptin) and pertuzumab (Perjeta) are widely used humanized monoclonal antibodies (mAbs) that have shown promise in treating patients with HER2-positive breast cancer. To enhance their effectiveness, mAbs have recently been combined with chemotherapeutic agents and radionuclides. The aim of our studies was to investigate the potential therapeutic use of trastuzumab and pertuzumab labeled with the Auger electron emitter – 125I.
Methods: The radioimmunoconjugates synthesized using 125I and 131I were tested in various in vitro studies on SKOV-3 cells. These studies included tests for specificity, binding affinity, internalization, cytotoxicity (MTS assay) and confocal imaging.
Results: The results confirmed that radio-iodinated mAbs have high affinity and internalization properties in an HER2+ cell line. In contrast to trastuzumab, significant localization of iodinated pertuzumab on the cell membrane was observed. MTS assay and spheroid studies demonstrated minor toxic effects from both radio-conjugates resulting from the combination of the mAbs' immuno-toxic effect and the interaction of Auger electrons. However, [125I]I-pertuzumab exhibited higher cytotoxicity.
Conclusions: Despite high internalization, both radio-bioconjugates showed low cytotoxicity due to the lack of radionuclide localization in the cell nucleus. However, [125I]I-pertuzumab accumulated in the cell membrane, resulting in slightly higher cytotoxicity. To improve therapeutic efficacy, modifying [125I]I-trastuzumab and [125I] I-pertuzumab to transport them to the cell nucleus, e.g., using nuclear localization signal (NLS) peptides, is crucial.

27-12-2024 - Original article
Narendra Rathod, Kriti Awasthi, Magdalena Kostkiewicz, Piotr Klimeczek, Ewa Stępień

Objectives: In order to increase diagnostic precision and efficiency in clinical settings, the goal is to assess how well sophisticated convolutional neural networks (CNNs) perform automated cardiac area recognition from chest X-ray pictures.
Methods: 496 high-resolution DICOM chest X-ray images (1024 x 1024) had been used as the dataset. Images were preprocessed, which included augmentation (e.g., scaling, rotation, contrast correction), normalization, and resizing. Metrics including Mean Squared Error (MSE) and Intersection over Union (IoU) were used to train and compare many CNN architectures (AlexNet, GoogLeNet, VGG-16, ResNet-18, and ResNet-50). The Adam optimizer was used in the training phase, with a batch size of 32 and 100 epochs. Validation was done on 96 images, and performance was measured with IoU scores and bounding box prediction accuracy.
Results: ResNet-50 outperformed the other models, with 93.2% accuracy and a mean IoU of 0.84 with very little variability. In terms of localization accuracy and training stability, the model outperformed alternative designs and demonstrated strong bounding box prediction abilities. The reliability of ResNet-50 in pinpointing specific cardiac regions under various imaging conditions is demonstrated by these results.
Conclusions: The study concludes by highlighting the revolutionary potential of deep learning in automating the detection of cardiac regions in chest X-rays. The best model turned out to be ResNet-50, which presented a big stride in incorporating AI-based solutions into diagnostic processes, especially in environments with limited resources. Combining detection and segmentation for improved diagnostic insights should be investigated in future studies.

27-12-2024 - Original article
Agnieszka Peła

Aim: The study aimed to develop an innovative algorithm for controlling a bionic hand prosthesis based on simultaneous analysis of electromyography (EMG) and electrical impedance myography (EIM) signals using continuous wavelet transform (CWT). The efficiency of both methods in motion classification was analyzed and compared, and the impact of electrode placement on classification accuracy was evaluated.
Methods: The BIOPAC MP36R system was employed to acquire EMG and EIM signals during six predefined hand movements from two distinct electrode placements. A total of 600 measurements were collected for each type of signal. Data were subjected to preliminary, time-domain, frequency-domain, and time-frequency analyses to extract key features for each movement. The developed classification algorithm utilized a k-nearest neighbors (k-NN) approach based on extracted signal features. The algorithm was trained on data obtained during the first measurement session and validated on an independent dataset.
Results: The results demonstrated that EIM signals outperformed EMG in motion classification accuracy, allowing for the differentiation of flexion and extension at the preliminary analysis stage. EIM achieved 100% accuracy in 9 out of 12 analyzed cases, with a minimum accuracy of 84%. In contrast, EMG signals enabled only basic movement detection without distinguishing between flexion and extension during the preliminary analysis phase. Electrode placement significantly affected classification performance, with differences exceeding 82% depending on placement.
Conclusions: The findings indicate the considerable advantage of EIM over traditional EMG in controlling bionic hand prostheses, opening new possibilities for more precise and intuitive control. The study also highlights the importance of optimal electrode placement to enhance the functionality of future bionic prostheses.

27-12-2024 - Original article
Barbara Wójcik, Jerzy Superata, Bryant Nguyen, Monika Weronika Piwowar, Zbigniew Szyguła

Objective: In this study, the gap was addressed in effective rehabilitation methodologies for preventing sepsis sequelae utilising a novel, two-way, diagnostically-monitored personalised rehabilitation model implemented to enhance quality of life (QoL) among sepsis survivors.
Methods: Of 66 sepsis survivors post-hospital discharge, and those who met the inclusion criteria, 30 were eventually allocated into three groups: a control group (Group C, n = 10, no rehabilitation) and two intervention groups undergoing three-month, diagnostically-monitored rehabilitation programmes. Group E (n = 10) received personalised aerobic and functional training, while Group H (n = 10) underwent intermittent hyperbaric oxygen therapy as a novel rehabilitative treatment alternative. QoL was evaluated at hospital discharge and again after 3 months using the newly developed Life After Sepsis Survey.
Results: After three months, statistically significant (p < 0.05) improvement was observed in QoL among sepsis survivors from both intervention groups concerning the significant parts of the assessed physiological, physical and psychological functions.
Conclusions: The personalised, patient-centric and supportive approach significantly improved QoL among sepsis survivors, highlighting the potential effectiveness of this rehabilitation model. The Life After Sepsis proved to be a practical assessment tool and currently stands as a uniquely suitable measure for evaluating sepsis rehabilitation outcomes.

27-12-2024 - Original article
Jacek Strzałkowski, Paweł Polak, Teodor Buchner


Objective: The objective of our study was to analyse the physics and mathematics of the coupling of cardiac sources to body volume and the impact of widespread assumptions on solutions of forward electrocardiographic problems.

Methods: Based on anatomical and physiological knowledge, we discuss the physical reality of the heart boundary and formulate a new way of setting boundary conditions of forward problems based on the boundary element method (BEM) within the SCIRun numerical package. This new type of boundary condition – the ”mixed” method approximating Neumann-Neumann, is compared to standard Dirichlet-Neumann conditions.

Results: By anatomical and physiological analysis, we show that there is strong evidence that mass transport, particularly charge transport through the pericardium, is negligible. On the physical ground, it should be assumed instead that the ECG signal spreads through the impermeable barrier as a displacement current that which assumes a nonzero normal component of potential gradient on the boundary. The numerical analysis shows that the new conditions give slightly better results than the standard ones. Notably, the quality of calculations is maintained, although the assumptions are different.

Conclusions: We claim that there are both physical and numerical arguments that the assumption that the normal component of a potential gradient must be zero at the heart and body border and can should be relaxed. These findings build convergence between the mathematical ideas and the physical reality of the electrolyte-filled human body. We aim to enhance the diagnostic impact of ECG-based approaches and advance our understanding of cardiac electrophysiology.

 
27-12-2024-Original article - Pages: 129 - 134

Advancing Cardiac Detection in Chest X-ray Images Using Machine Learning: A Practical Application of AI in Medical Imaging

  • 1. University of Bern and Inselspital, Clinic for Nuclear Medicines, Bern, Switzerland
  • 2. Doctoral School of Medical and Health Sciences, Jagiellonian University Collegium Medicum, Kraków, Poland; Department of Medical Physics and Centre for Theranostics, Jagiellonian University, Kraków, Poland
  • 3. Heart and Vascular Disease Clinics, Jagiellonian University Collegium Medicum, Kraków, Poland
  • 4. Department of Radiology, Specialist Hospital Ludwik Rydygier in Kraków, Poland
  • 5. Department of Medical Physics and Centre for Theranostics, Jagiellonian University, Kraków, Poland
Sent to editorial office:14-11-2024
Accepted after review:23-12-2024
Published:27-12-2024

Language versions:
54
588
DOI:10.5604/01.3001.0054.9269
GICID:01.3001.0054.9269


 

ABSTRACT

Objectives: In order to increase diagnostic precision and efficiency in clinical settings, the goal is to assess how well sophisticated convolutional neural networks (CNNs) perform automated cardiac area recognition from chest X-ray pictures.
Methods: 496 high-resolution DICOM chest X-ray images (1024 x 1024) had been used as the dataset. Images were preprocessed, which included augmentation (e.g., scaling, rotation, contrast correction), normalization, and resizing. Metrics including Mean Squared Error (MSE) and Intersection over Union (IoU) were used to train and compare many CNN architectures (AlexNet, GoogLeNet, VGG-16, ResNet-18, and ResNet-50). The Adam optimizer was used in the training phase, with a batch size of 32 and 100 epochs. Validation was done on 96 images, and performance was measured with IoU scores and bounding box prediction accuracy.
Results: ResNet-50 outperformed the other models, with 93.2% accuracy and a mean IoU of 0.84 with very little variability. In terms of localization accuracy and training stability, the model outperformed alternative designs and demonstrated strong bounding box prediction abilities. The reliability of ResNet-50 in pinpointing specific cardiac regions under various imaging conditions is demonstrated by these results.
Conclusions: The study concludes by highlighting the revolutionary potential of deep learning in automating the detection of cardiac regions in chest X-rays. The best model turned out to be ResNet-50, which presented a big stride in incorporating AI-based solutions into diagnostic processes, especially in environments with limited resources. Combining detection and segmentation for improved diagnostic insights should be investigated in future studies.

 

LIST OF ABBREVIATIONS

AI – Artificial Intelligence
CNN – Convolutional Neural Network
IoU – Intersection over Union
MSE – Mean Squared Error
NIH – National Institutes of Health

 

INTRODUCTION

The intersection of artificial intelligence and medical imaging represents a frontier of innovation in modern healthcare. Chest X-rays, being one of the most frequently performed diagnostic imaging procedures worldwide, present a unique opportunity for implementing AI-driven solutions to enhance clinical decision-making [1]. The accurate detection and delineation of the cardiac region within these images is crucial for diagnosing various cardiopulmonary conditions, including cardiomegaly, pneumothorax, and positional abnormalities [2].

The exponential growth in medical imaging data, coupled with advances in computational capabilities, has created unprecedented opportunities for developing sophisticated automated diagnostic tools. In particular, the application of deep learning to chest X-ray analysis has shown remarkable potential in augmenting clinical expertise. Our research focuses on the specific challenge of cardiac region detection, which requires precise localisation and boundary definition within chest X-ray images. This study leverages stateof-the-art deep learning architectures to develop a robust system for cardiac region detection. By utilising a carefully curated dataset of 496 DICOM images [1], we explore the capabilities of various convolutional neural network architectures, with particular emphasis on the different Convolutional Neural Network (CNN) models. Our approach incorporates sophisticated preprocessing techniques and data augmentation strategies to enhance model performance and generalisability [3].

Despite significant advances in medical imaging, identifying cardiac regions with precision remains a challenge due to the complexity of anatomical structures and the dependency on expert radiological interpretation. This challenge is particularly pronounced in resource- -limited settings, where the shortage of trained professionals limits access to timely and accurate diagnostics. Automated cardiac region detection, powered by deep learning, has emerged as a potential solution to streamline diagnostic workflows, reduce interpretation time, and improve the detection of cardiac abnormalities. This study not only addresses the need for efficient cardiac imaging solutions but also contributes to the broader field of medical image analysis by demonstrating the applicability of different deep learning techniques to anatomical detection tasks. The methodologies developed here provide a foundation for future innovations in automated diagnostic systems, with potential applications across various imaging domains [4, 5].

Source and Data Description

The dataset utilised in this study, ChestX-ray8, originates from the research “ChestX-ray8: Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases” by Xiaosong Wang and colleagues at the National Institutes of Health (NIH) Clinical Centre [1, 3]. ChestX-ray8 comprises over 100,000 frontal-view chest X-ray images from 32,717 unique patients, with 496 images annotated with bounding boxes [6–8] and coordinates (x0,y0,w,h) around pathological regions. These annotations enable localisation tasks, which are critical for training deep learning models in medical image analysis. The dataset, publicly accessible on platforms such as Kaggle (e.g., the RSNA Pneumonia Detection Challenge) [https://www.kaggle.com/code/younesselbrag/cardiac-detectionpeunomian-bounding-box-c orrds], provides a robust foundation for advancing computer-aided diagnostic techniques.

Bounding boxes, rectangular frames defined by coordinates (x0,y0) (top-left corner) and dimensions (w, h) (width and height), are fundamental tools in medical imaging. They delineate regions of interest, such as organs or abnormalities, enabling algorithms to isolate these areas for detection and classification tasks. Fig. 1. illustrates some sample chest X-ray images with bounding boxes highlighting areas of interest. Bounding boxes can be created and manipulated using various Python libraries, including TensorFlow and PyTorch, which offer functions for defining, visualising, and scaling bounding boxes. These tools are pivotal in medical imaging workflows, supporting the development of accurate and efficient deep learning models.

Alternate image: Fig. 1. Visualisation of cardiac region detection in chest X-ray scans. The im ...

Fig. 1. Visualisation of cardiac region detection in chest X-ray scans. The images show 15 different chest images with red bounding boxes highlighting the cardiac silhouette. The detection demonstrates consistent localisation of the heart region across varying patient anatomies and imaging conditions.

 

MATERIALS AND METHODS

Dataset Characteristics, preparation and pre-processing pipeline

The research utilises a comprehensive dataset comprising 496 high-resolution DICOM chest X-ray images. Each image contains detailed cardiac region annotations marked by bounding box coordinates. The images undergo resizing from 1024 × 1024 pixels to 224 × 224 pixels using bilinear interpolation, ensuring minimal information loss during downscaling. This standardisation maintains computational efficiency while retaining sufficient detail for accurate cardiac region detection. The pixel intensities are normalised to the range [0,1] through scaling with a factor of 1/255, establishing consistent input distributions across the dataset and facilitating stable model training. The dataset organisation follows a strategic split, with 400 images dedicated to training and 96 images reserved for validation.

Data Augmentation Strategy and Training Protocol Implementation

To enhance model robustness and mitigate overfitting, data augmentation techniques were applied. These include contrast enhancement (ranging from 0.7–1.7), and geometric transformations encompassing scaling (0.8 to 1.2), rotation (–10° to 10°), and translation (–10 to 10 pixels), simulating real-world variations such as differing heart sizes, patient positioning, and exposure conditions.

The training protocol utilises the Adam optimizer with a learning rate of 1 x 10-4 and beta parameters (0.9, 0.999). The training spans 100 epochs with a batch size of 32, incorporating validation checks after each epoch. The checkpoints were set after every 20 epochs in order to monitor performance. The Mean Squared Error (MSE) [9] loss function directly optimises coordinate prediction accuracy, while the Matthews Correlation Coefficient [10, 11] serves as the primary evaluation metric. Additional performance assessments include Intersection over Union (IoU) calculations to measure the bounding box precision.

Model archtectures and peformance analysis

The study compared the performance of four deep learning architectures:

  1. AlexNet: An 8-layer network with five convolutional layers and three fully connected layers, employing ReLU activation and dropout for overfitting prevention [12].
  2. GoogLeNet: A 22-layer architecture featuring Inception modules that process multiple filter sizes in parallel, enabling efficient multi-scale feature extraction [13].
  3. VGG-16: A 16-layer network employing uniform 3 × 3 convolutional filters and max pooling, emphasising architectural simplicity and depth for robust feature learning [14].
  4. ResNet: Incorporating residual blocks with skip connections, ResNet mitigates vanishing gradient issues, enabling deeper networks. ResNet-50, with 50 layers, demonstrated superior feature extraction capabilities for this task [15].

 

RESULTS

ResNet-50 outperformed other architectures in both loss reduction and accuracy. Fig. 2. demonstrates that ResNet-50 achieved the lowest loss and consistently high accuracy throughout training, outperforming GoogLeNet, ResNet-18, and AlexNet. The deeper architecture of ResNet-50 enabled superior feature extraction, critical for accurate cardiac region detection.

Alternate image: Fig. 2. The left graph shows loss values on y-axis and x-axis represents the s ...

Fig. 2. The left graph shows loss values on y-axis and x-axis represents the steps (iteration with each epoch) during training and the right graph indicates accuracy trends on y-axis (x-axis remains the same as the left graph), highlighting the fact that ResNet-50 performs better than all other models.

Colour Key: Light Blue – AlexNet, Magenta – GoogLeNet, Pink – ResNet-18, Yellow – ResNet-50, Green – VGG-16.

Fig. 3. provides detailed insights into ResNet-50’s predictive per formance. The left panel compares the prediction distributions of bounding box parameters across models, with ResNet-50 exhibiting minimal variability and higher precision. The right panel highlights ResNet-50’s accuracy through histograms of absolute differences between predicted and true bounding box parameters, showing minimal errors across all dimensions (x0,y0,w,h).

Alternate image: Fig. 3. The left figure displays the aggregated sum of all predicted parameter ...

Fig. 3. The left figure displays the aggregated sum of all predicted parameters defining the bounding boxes – coordinates (x₀, y₀), width (w), and height (h) – for each of the selected models. The right figure highlights the detailed results for ResNet-50, showcasing its superior predictions for each parameter individually, thereby emphasising its effectiveness in bounding box localisation.

These results underscore ResNet-50’s comparative reliability and robustness in medical imaging applications, providing precise localisation of regions of interest.

 

DISCUSSION

This study provides valuable insights into the comparative performance of five prominent CNN architectures for cardiac region detection in chest radiographs.

Our evaluation, driven by IoU metrics, establishes a clear performance ranking, with GoogLeNet and ResNet-50 emerging as the most effective models for precise cardiac localisation. This is largely attributed to key architectural advancements, such as Inception modules in GoogLeNet and residual connections in ResNet-50, which enable both efficient feature extraction and enhanced localisation capabilities. These innovations significantly improve the model’s ability to accurately identify and delineate cardiac structures, addressing one of the most challenging tasks in medical imaging.

From a clinical perspective, the precision of cardiac region detection is pivotal for diagnosing conditions such as cardiomegaly and other cardiac abnormalities. ResNet-50, in particular, demonstrated superior stability with a low IoU standard deviation of 0.074, suggesting that it can maintain high accuracy across varying patient anatomies. This consistency is crucial in clinical environments, especially in resource-limited settings where expert radiological interpretation may be scarce. The high IoU scores achieved by both ResNet-50 and GoogLeNet models enable not only accurate localisation but also detailed analysis of cardiac structures, enhancing the quality of clinical diagnoses (Fig. 4.).

Alternate image: Fig. 4. This figure displays chest X-ray images with bounding boxes indicating ...

Fig. 4. This figure displays chest X-ray images with bounding boxes indicating model predictions. The red bounding box represents a TRUE prediction, while the green bounding boxes indicate from various models: A – VGG-16, B – ResNet-18, C – ResNet-50, D – AlexNet, and E – GoogLeNet.

The findings highlight the potential of deep learning models to improve both the accuracy and reliability of cardiac identification, making them suitable for real-world diagnostic applications. Future research could focus on integrating segmentation techniques with detection models to enable more detailed analysis of organs, lesions, and tumours. By incorporating multimodal imaging and leveraging larger datasets, the accuracy and generalisability of these models can be further improved. Overall, this study marks a significant step forward in the integration of deep learning into clinical workflows, offering the potential for more efficient and precise cardiac diagnostics in diverse healthcare settings.

 

CONCLUSIONS

This study demonstrates the transformative potential of machine learning, particularly deep learning, in advancing medical image analysis. By leveraging sophisticated CNN architectures, such as ResNet-50 and GoogLeNet, we have shown that machine learning models can significantly enhance the precision and reliability of cardiac region detection in chest radiographs (Tab. I.). The application of advanced feature extraction techniques and robust evaluation metrics like IoU has proven essential in improving model performance, enabling accurate localisation and detailed analysis of cardiac structures.

Alternate image: Tab. I. Table summarises the performance evaluation of various convolutional n ...

Tab. I. Table summarises the performance evaluation of various convolutional neural network architectures, highlighting differences in accuracy, mean Intersection over Union (IoU) prediction, standard deviation of IoU prediction, and the number of parameters. The final column provides insights into the computational requirements associated with each model, indicating potential implications for training time and resource allocation.

Machine learning, through its ability to process and analyse large volumes of medical imaging data, holds substantial promise for addressing key challenges in healthcare, such as early detection, diagnostic accuracy, and workflow efficiency. The automation of tasks like organ identification and pathology detection not only alleviates the burden on radiologists but also facilitates faster, more accurate diagnoses, particularly in underserved regions with limited access to expert care [13]. As machine learning models continue to evolve, integrating multi-modal data and expanding datasets will further enhance their capabilities, enabling more comprehensive analyses of medical images and improving patient outcomes [16, 17]. This work underscores the critical role of machine learning in the future of medical diagnostics, paving the way for smarter, more efficient healthcare solutions worldwide.

ACKNOWLEDGEMENT

This work was supported by the National Science Centre of Poland through grant no. 2022/47/I/NZ7/03112 (E.Ł.S.), the Jagiellonian University via projects CRP/0641.221.2020, SciMat, and qLife Priority Research Areas budget under the program Excellence Initiative – Research University (Centre for Theranostics), and by the SNF grant number 216944 affiliated with the University of Bern – BE and Universitätsklinik für Nuklearmedizin Inselspital Bern.

Supplementary information – The available codes for the following analysis are available at https://github.com/NSRathod/ML-in-Cardiac-identification-using-bounding-box.git

References:

1.
Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM. ChestX-ray8:Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases.2017; arXiv:1705.02315.
2.
Lakhani P, Sundaram B. Deep Learning at Chest Radiography: Automated Classification of Pulmonary Tuberculosis by Using Convolutional Neural Networks. Radiology. 2017;284(2):574–82. doi: https://doi.org/10.1148/radiol.2017162326.
3.
He Y, Zhu C, Wang J, Savvides M, Zhang X. Bounding Box RegressionWith Uncertainty for Accurate Object Detection. 2019;arXiv:1809.08545.
4.
Topol EJ. High-performance medicine: the convergence of human and artificial intelligence. Nat Med. 2019;25(1):44–56. doi: https://doi.org/10.1038/s41591-018-0300-7.
5.
Litjens G, Kooi T, Bejnordi BE, Setio AAA, Ciompi F, Ghafoorian M, etal. A survey on deep learning in medical image analysis. Med ImageAnal. 2017;42:60–88. doi: https://doi.org/10.1016/j.media.2017.07.005.
6.
Bista R, Timilsina A, Manandhar A, Paudel A, Bajracharya A, Wagle, S,et al. Advancing Tuberculosis Detection in Chest X-rays: A YOLOv7-Based Approach. Information. 2023;14:655.
7.
Franquet T. Imaging of Community-acquired Pneumonia. J Thorac Imaging.2018;33(5):282–94. doi: https://doi.org/10.1097/RTI.0000000000000347.
8.
Kelly B. The chest radiograph. Ulster Med J. 2012;81(3):143–8.
9.
Kingma DP, Ba J. Adam: A Method for Stochastic Optimization.2014;arXiv:1412.6980.
10.
Chicco D, Jurman G. The advantages of the Matthews correlation coefficient (MCC) over F1 score and accuracy in binary classification evaluation. BMC Genomics. 2020;21(1):6. doi: https://doi.org/10.1186/s12864-019-6413-7.
11.
Ren S, He K, Girshick R, Sun J. Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks. IEEE Trans Pattern AnalMach Intell. 2017;39(6):1137–49. doi: https://doi.org/10.1109/TPAMI.2016.2577031.
12.
Krizhevsky A, Sutskever I, Hinton GE. ImageNet classification withdeep convolutional neural networks. Communications of the ACM.2017;60(6):84–90. doi: https://doi.org/10.1145/3065386.
13.
Szegedy C, Liu W, Jia Y, Sermanet P, Reed S, Anguelov D. Going deeper with convolutions. In: Conference on Computer Vision and Pattern Recognition (CVPR): 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR); 2015 June 7–12; Boston, MA,USA. New Jersey: IEEE; 2015. pp. 1–9. doi: https://doi.org/10.1109/CVPR.2015.7298594.
14.
Liu S, Deng W. Very deep convolutional neural network based imageclassification using small training sample size. In: 3rd IAPR Asian Conference on Pattern Recognition (ACPR): 2015 3rd IAPR Asian Conferenceon Pattern Recognition (ACPR); 2015 Nov 3–6; Kuala Lumpur, Malaysia. New Jersey: IEEE; 2015. pp. 730–4. doi: https://doi.org/10.1109/ACPR.2015.7486599.
15.
He K, Zhang X, Ren S, Sun J. Deep Residual Learning for Image Recognition. In: 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR): 2016 IEEE Conference on Computer Vision and Pattern Recognition; 2016 June 27–30; Las Vegas, NV, USA: IEEE; 2016.pp. 770–8. doi: https://doi.org/10.1109/CVPR.2016.90.
16.
Mingxing T, Le Q. Efficient Net: Rethinking model scaling for convolutional neural networks. 2019;arXiv:1905.11946.
17.
Howard AG, Zhu M, Chen B, Kalenichenko D, Wang W, Weyand T, et al.MobileNets: Efficient Convolutional Neural Networks for Mobile VisionApplications. 2017; arXiv:1704.04861.