21-11-2024 - Original article - Pages: 1 - 9
Faranak Tayefi Ardebili, Paweł Moskal

Introduction: The presented study evaluates the spatial resolution of the Modular J-PET scanner using the National Electrical Manufacturers Association (NEMA) NU2-2018 standard. The Modular J-PET, constructed with BC-404 plastic scintillators in an axial arrangement and coupled with analogue Silicon Photomultipliers (SiPMs) at both ends, offers a 50 cm axial field of view and a bore diameter of 73.9 cm. The study compares results from GATE simulations with experimental data.
Objective: The primary objective of this study is to assess the spatial resolution of the Modular J-PET scanner, using Time-of-Flight (TOF) and non-TOF image reconstruction, based on NEMA NU2-2018 guidelines.
Methods: Spatial resolution was evaluated using a Na-22 point-like source as recommended by NEMA NU2-2018. Both TOF and non-TOF list mode acquisitions were performed, with a comparative analysis of the results from experimental and simulated data.
Results: Radial spatial resolution, obtained based on the experimental data when taking into account TOF, is equal to 4.92 ± 0.56 mm, 7.38 ± 0.49 mm, and 6.94 ± 0.38 mm at positions 1 cm, 10 cm, and 20 cm from the detector centre, respectively. The tangential spatial resolution for TOF image reconstruction was determined as 7.38 ± 0.51 mm, 7.37 ± 0.10 mm, and 14.67 ± 0.31 mm at the same positions based on experimental data, while axial spatial resolution was calculated as 30.73 ± 0.52 mm, 30.73 ± 0.64 mm, and 31.96 ± 0.29 mm based on experimental data. Simulated radial spatial resolution for TOF image reconstruction methods was found to be 4.80 ± 0.59 mm, 7.26 ± 0.55 mm, and 6.67 ± 0.42 mm at positions 1 cm, 10 cm, and 20 cm from the detector centre, respectively. The simulated tangential spatial resolution for TOF image reconstruction methods was determined as 7.27 ± 0.47 mm, 7.27 ± 0.59 mm, and 15.1 ± 0.4 mm at the corresponding positions, while the simulated axial spatial resolution was determined as 29.97 ± 0.49 mm, 30.53 ± 0.74 mm, and 31.78 ± 0.11 mm.
Conclusions: The Modular J-PET meets NEMA NU2-2018 standards, with TOF mode providing better spatial resolution than non-TOF, validating the system’s high-resolution imaging capabilities.

Language versions:
64193
DOI: 10.5604/01.3001.0054.8095
GICID: 01.3001.0054.8095
26-11-2024 - Original article - Pages: 10 - 16
Pragya Das, Ritesh Verma, Kaustav Prasad

Objective: To demonstrate the potential of PET imaging using scattered photons, we have proposed a novel technique that utilizes single-tissue-scattered events based solely on time-of-flight (TOF) information, without relying on energy data. Additionally, we explored the possibility of improving image quality by applying polarization selection criteria for true events.
Methods: Due to Compton scattering within the phantom, scattered photons exhibit reduced energy, which remains unknown in our analysis. For a fixed scattering angle, the locus of the scattering point forms an arc of a circle in two dimensions (2D). With known TOF, we can trace the locus of the annihilation point for all possible scattering angles and positions. Our procedure involves identifying the annihilation-point loci corresponding to all pairs of single-scattered photons and merging them. In a separate study, we utilized the classical concept of orthogonal polarization of two annihilation photons, combined with energy filtering, to select genuine (true) events.
Results: Our proof-of-concept study successfully demonstrated that the TOF-based approach could yield an image of a point source. The merging of annihilationpoint loci from numerous pairs of single-scattered photons produced a localized region for the source activity. The intensity profile showed a finite width of 14 mm for 1 ps uncertainty in TOF. Additionally, another analysis utilizing polarization and energy criteria generated a clean dataset for true events, with minimal background interference (containing random coincidences) at a high event rate.
Conclusions: The simulation-based study validated our proposed model, indicating its potential to enhance the sensitivity and accuracy of event selection in PET imaging. These findings lay a solid foundation for further research into advanced PET imaging techniques that incorporate single-scattered events.

Language versions:
81171
DOI: 10.5604/01.3001.0054.8576
GICID: 01.3001.0054.8576
11-12-2024 - Original article - Pages: 17 - 26
Karol Lang

Objective: The in-vivo therapy guidance by imaging and dosimetry of proton irradiations, generically known as proton range verification, are some of the most underinvested aspects of radiation oncology. They trail behind other advances in radiation therapy due to the scarcity of sensitive instruments compounded by the lack of treatment protocols for precision monitoring of effects of beam radiation. This is despite that such measurements may dramatically enhance the treatment accuracy and lower the postradiation toxicity, thus improving the entire outcome of cancer therapy.
Methods: In this contribution, we focus on the motivation of designing and building of an in-beam time-of-flight (ToF) positron-emission-tomography (PET) scanner with the depth-of-interaction (DoI) capability for high sensitivity and improved fidelity of imaging. A scanner could be augmented with a tungsten collimator that would enable prompt-gamma imaging (PGI) via single-photon emission computed tomography (SPECT) technique.
Results: We present selected results of our pre-clinical experiments with a FLASH proton beam and discuss other related ideas towards improving and expanding the use of PET/PGI/SPECT detectors for proton therapy. A scanner provides an access to data during the spill and past the spill permitting to capture the beam interaction and kinetic monitoring of its effect thus allowing a thorough assessment of each irradiation.
Conclusions: A novel scanner for multiple modalities can substantially improve the treatment precision of proton therapy leading to less toxic outcome of irradiations. Using it in the FLASH modality would additionally expand the patient reach of proton therapy.

Language versions:
48664
DOI: 10.5604/01.3001.0054.8930
GICID: 01.3001.0054.8930
17-12-2024 - Original article - Pages: 27 - 34
Gregory R. Romanchek, Greyson Shoop, Matthew A. Kupinski, Phillip H. Kuo, Michael King, Lars R. Furenlid, Shiva Abbaszadeh


Objective: We assess the viability of using quantum entanglement (QE) information for improving event classification in a combined PET-Compton Camera (PET-CC) system, particularly in the potential for distinguishing true positron annihilation events from Random events due to prompt gamma contamination for β+ and γ emitting isotopes.
Methods: Monte Carlo GATE simulations were performed to evaluate the sensitivity and accuracy of event classification in various scenarios using ground truth data, including standard PET events and Compton Camera interactions. QE-sensitive data subsets were identified and filtered based on either polar scattering angles (θ) or the energy of the initial Compton scatter (EC). The enhancement ratio – ratio of the difference of azimuthal scattering at Δφ = 90° and 0° – and fraction of post-filter Trues were used as metrics.
Results: The simulations showed that QE information could assist in resolving energy ambiguities, particularly in cases where prompt gamma emissions complicate event pairing. Filtering based on EC provided a higher enhancement ratio (R ≈ 1.8) compared to θ-based filtering (R ≈ 1.4), indicating better discrimination between True and Random events. The ratio of Trues to Total events passing the EC filter (0.837) greatly improved upon that of the θ-based filter (0.541).
Conclusions: Our results suggest that energy-based filtering is more effective in leveraging QE information, but further refinement of filtering algorithms is needed to fully realize its benefits. While QE has the potential to improve event classification in PET-CC systems for a few coincidence cases, further studies are needed to utilize this paradigm in image formation.

Language versions:
53795
DOI: 10.5604/01.3001.0054.9079
GICID: 01.3001.0054.9079
18-12-2024 - Short communication - Pages: 35 - 39
Karol Kubat, Łukasz Kapłon, Paweł Moskal, Ewa Stępień

Objective and method: Positron annihilation lifetime spectroscopy (PALS) is a powerful technique in material science that allows the investigation of the properties and behavior of positrons in various materials. PALS can be used to investigate solid structures at the nanometer scale and enable the use of positronium properties as an additional diagnostic parameter. Here we present results from calibration of the PALS system with certificated reference materials (CRM).
Materials: Source of 22Na covered with layer of Kapton film, and after that parafilm from both sides was used in all experiments. Certified materials of No_5602-a (polycarbonate) and No_5601-a (fused silica) were used to ascertain if parameters were correctly identified.
Results: In an experiment three lifetime components were correctly identified. All of those components will always be present in the data in further experiments on biological samples. Lifetime components consist of: 196 ps for annihilations in AI an aluminium cover of the chamber, 386 ps for annihilations in thesource and in the Kapton foil, 463 ps for reactions with parafilm.
Conclusions: These parameters will be further used to correctly identify positron lifetimes in biological samples. Recently, a new method for imaging of positronium properties was invented and the first in-vivo images of positronium lifetime in humans were demonstrated with the multi-photon J-PET scanner. In order to correlate the positronium properties in tissue with the medically useful parameters, and to translate positronium imaging to clinics, comprehensive research of positronium properties in biological samples is needed.

Language versions:
43150
DOI: 10.5604/01.3001.0054.9091
GICID: 01.3001.0054.9091
23-12-2024 - Original article - Pages: 40 - 48
Lucas Berens, Isaac Hsu, Chin-Tu Chen, Howard Halpern, Chien-Min Kao

Objective: The presence of tumor hypoxia is known to correlate with poor patient prognosis. Measurement of tissue oxygen concentration can be challenging, but recent advancements using positron annihilation lifetime spectroscopy (PALS) in three-dimensional positron emission tomography (PET) scans have shown promise for hypoxia detection. In this work, a novel method for estimating the orthopositronium lifetime in PALS is presented.
Methods: We have developed an analytical method based on moments of the PALS histogram to estimate the orthopositronium lifetime. The method was characterized with respect to estimation bias and variance, and the bias-minimizing moments were found for various orthopositronium lifetimes.
Results: For sufficient statistical power, the method produces monotonic, stable estimates. For cases with a lower number of photon counts, the method was characterized, and solutions are presented to correct for bias and estimation variability. For most cases, the bias-minimizing moments were n = 10, 11, 12.
Conclusions: This novel method does not require curve-fitting and thus it is less computationally intensive than methods which fit the PALS histogram. This method will be extended to and continue to be improved for use in positronium lifetime imaging.

Language versions:
50947
DOI: 10.5604/01.3001.0054.9141
GICID: 01.3001.0054.9141
23-12-2024 - Short communication - Pages: 49 - 54
John P. Cesar, Firas Abouzahr, Paulo Crespo, Michael Gajda, Alex Kuo, Osama Mawlawi, Andrey Morozov, Aryan Ojha, Falk Poenisch, Marek Proga, Narayan Sahoo, Joao Seco, Takeshi Takaoka, Stefaan Tavernier, Uwe Titt, Xiaochun Wang, Xiaorong Zhu, Karol Lang

Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect.
Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics.
Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam.
Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities.
Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.

Language versions:
39755
DOI: 10.5604/01.3001.0054.9140
GICID: 01.3001.0054.9140
27-12-2024 - Original article - Pages: 55 - 62
Paweł Moskal, Ewa Stępień, Aleksander Khreptak

Objectives: This paper presents the prospects for increasing the availability of PET diagnostics by combining low-cost, lightweight and easily portable modular J-PET with the 44Ti/44Sc generator.
Methods: J-PET is constructed based on the low-cost axially arranged plastic scintillators that may enable the construction of PET scanners 5 to 10 times less expensive compared to current PET systems, which are based on crystal scintillators. Development of the radionuclide 44Ti/44Sc generator with the 60-year half-lifetime would enable long-term onsite production of 44Sc labelled radiopharmaceuticals, eliminating the need for extensive and costly infrastructure typically associated with nuclear medicine. Presently applied 68Ge/68Ga generators with the 270 days half-lifetime require renewal every year. The 44Ti/44Sc generator could, in principle, be purchased once every half century.
Results: The lightweight and portable J-PET scanner, combined with the 44Ti/44Sc generator, can be deployed in remote and underserved regions, thus democratising access to advanced medical-imaging techniques.
Conclusions: This novel concept shows the transformative potential of combining innovative J-PET technology with the 44Ti/44Sc generator to make advanced diagnostics more accessible and affordable worldwide, especially benefiting millions of patients in low- and medium-income countries, and driving further innovations in medical imaging.

Language versions:
849106
DOI: 10.5604/01.3001.0054.9273
GICID: 01.3001.0054.9273
27-12-2024 - Original article - Pages: 63 - 70
Ali Dinari, Hafiz Ashfaq Ahmad, Minh Phú Bùi, Seungjun Oh, Yun-Hee Kim, Dae-Hong Kim, Jungwon Yoon

Objective: Pancreatic cancer is an asymptomatic disease and, based on statistical studies, it is the fourth leading cause of cancer-related death. Pancreatic ductal adenocarcinoma (PDAC), which accounts for over 95% of pancreatic cancers, is typically detectable at advanced stages. Standard diagnostic methods include bloodbased tests and imaging. Standard diagnostic methods include blood-based tests and imaging. Biomarkers play a key role as indicators in blood tests, offering valuable insights into disease detection and monitoring. Mesothelin, a cell-surface glycoprotein, and vimentin, an intermediate filament protein, are promising biomarker candidates.
Methods: In this study, these biomarkers were conjugated with magnetic nanoparticles (MNPs) and utilized for cellular tracking through magnetic particle spectroscopy (MPS). Capan-1 (a pancreatic cancer cell line) and bone marrow stem cells (BMSC) were treated with the targeted MNPs. Subsequently, MNP-labelled cells were evaluated with imaging modalities such as MPS and confocal microscopy.
Results: In the case of the MPS modality, a home-made MPS device with a detection limit of 1 ng of MNPs was used. The results showed that MPS can quantitatively trace MNPs signals and differentiate between various treatments.
Conclusions: Detection of labelled cells via MPS is a novel method with features such as sensitivity, non-invasiveness, and no background noise. This new technology can pave the way for imaging quantification of pancreatic cancer in its primary stages and for tracking cancer cell populations. populations.

Language versions:
34645
DOI: 10.5604/01.3001.0054.9363
GICID: 01.3001.0054.9363
Featured article
31-05-2026 - Original article
Paweł Moskal

Objective: Hypoxia is a critical factor in tumour aggressiveness, metastasis, and treatment resistance. Despite its clinical significance, a non-invasive, high-precision method for assessing and mapping tissue oxygenation in vivo remains a major challenge in medicine.This study explores the potential of positronium imaging and quantum entanglement (QE) imaging as next-generation biomarkers for hypoxia. This manuscript introduces a novel method to assess tissue oxygen concentration via the QE of photons originating from positronium – a bound state of an electron and a positron – which is produced within the patient’s body during positron emission tomography (PET). We also investigate the possibility of assessing hypoxia by simultaneously detecting positronium lifetime and the positronium decay rate ratio.

Methods: We introduce two distinct quantum sensing approaches. Method 1 utilises the correlation between oxygen concentration and ortho-positronium (o-Ps) decay rates, relying on the simultaneous measurement of the mean o-Ps lifetime (τoPs) and the 3γ-to-2γ annihilation rate ratio of o-Ps (RoPs-3γ/2γ). Method 2 introduces a novel hypothesis based on the degree of QE of annihilation photons. This method leverages recent discoveries indicating that the degree of QE is sensitive to the relative contribution of annihilation mechanisms (pick-off vs. conversion), which in turn depends on the oxygen concentration. We estimate the rate of conversion processes as a function of the partial pressure of oxygen (pO2) in water, isopropanol, cyclohexane, isooctane, and adipose tissue. We consider dependence of RoPs-3γ/2γ and τoPs, as well as the degree of QE, on oxygen pressure in the studied substances. Finally, we derive a formula for pO2 as a function of RoPs-3γ/2γ and τoPs and estimate the measurement accuracy required for these parameters – and for the degree of QE – to sense in-vivo oxygen pressure in the range between hypoxic and physoxic conditions.

Results: Theoretical models and quantitative estimates for RoPs-3γ/2γ, τoPs and for the degree of QE (CQE and RQE) as a function of pO2 are provided for water, organic solvents (isopropanol, cyclohexane, isooctane), and adipose tissue. Applying the formulas derived under the working hypothesis that in pick-off process the photons are not entangled, we estimated that for pO2 = 0, the degree of QE CQE is equal to 0.890 for adipose, 0.886 for isopropanol, 0.867 for water, 0.818 for cyclohexane, and 0.784 for isooctane. These results indicate that distinguishing between various tissue types requires a precision of σ(CQE) ≈ 0.01. We also estimated the values of τoPs, RoPs-3γ/2γ, and R3γ/2γ, as well as the changes in τoPs, RoPs-3γ/2γ and CQE between physoxic (pO2 ≈ 50 mmHg) and hypoxic (pO2 = 10 mmHg) conditions amount to ΔτoPs = 5 ps (water), 48 ps (adipose), 182 ps (isopropanol), 187 ps (cyclohexane), 444 ps (isooctane), ΔRoPs-3γ/2γ = 0.000045 (water), 0.0004 (adipose), 0.0015 (isopropanol), 0.0015 (cyclohexane), 0.0036 (isooctane), and ΔCQE = 0.0003 (water), 0.0019 (adipose), 0.0054 (isopropanol), 0.0106 (cyclohexane), 0.0243 (isooctane). To distinguish between physoxic and hypoxic conditions in vivo, the measurement precision σ(τoPs), σ(RoPs-3γ/2γ) and σ(CQE) must be several times higher than the predicted changes in these values.

Conclusions: This work establishes a theoretical and methodological foundation for using the QE of photons and the properties of positronium as transformative diagnostic tools for the non-invasive assessment and mapping of tissue oxygenation in the human body. It demonstrates that QE can serve not only as a tool for improving PET image quality through noise reduction, but also as a completely new category of biomarker. Quantitative estimations of the effect of oxygen pressure on positronium parameters, as well as the event statistics required for hypoxia assessment, are feasible using the multi-photon total-body J-PET scanner based on plastic scintillators. Furthermore, such assessments will be possible with next-generation, high-sensitivity crystal-based PET scanners, provided they are upgraded to support multi-photon signal acquisition for τoPs and 3γ-to-2γ imaging, and double Compton scattering for imaging CQE – the degree of QE.


878159
DOI: 10.5604/01.3001.0055.7461
22-04-2026 - Original article
Krzysztof Kacprzak, Ermias Beyene, Jarosław Choiński, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Manish Das, Jakub Hajduga, Sharareh Jalali, Tevfik Kaplanoglu, Łukasz Kapłon, Kamila Kasperska, Aleksander Khreptak, Grzegorz Korcyl, Tomasz Kozik, Karol Kubat, Sumit Kumar Kundu, Deepak Kumar, Edward Lisowski, Filip Lisowski, Justyna Mędrala-Sowa, Simbarashe Moyo, Wiktor Mryka, Szymon Niedźwiecki, Anand Pandey, Piyush Pandey, Szymon Parzych, Alessio Porcelli, Bartłomiej Rachwał, Martin Rädler, Sushil Sharma, Magdalena Skurzok, Anna Stolarz, Tomasz Szumlak, Pooja Tanty, Keyvan Tayefi Ardebili, Satyam Tiwari, Anoop Venadan, Ewa Stępień, Paweł Moskal


Objective: The goal of the work is to develop a set of methods for calibrating the positron emission tomography system built from plastic scintillators, and to present the results of the modular J-PET scanner time of flight (TOF) and time over threshold (TOT) synchronisation.

Methods: Measurements with radionuclide 22Na and 44Sc (used as a point-like source and enclosed in a collimator) were performed using the modular J-PET scanner, which detects signals from annihilation photons and prompt gamma. The data were gathered with a trigger-less data acquisition system and analysed with a dedicated software framework. The detection modules were synchronised with the procedures, correcting time offsets and normalising TOT measurements.

Results: The application of the time calibration methods yields a fully synchronised detector that is capable of producing the image of the source. TOF resolution for modular J-PET is determined to be about 490 ps (FWHM).

Conclusions: The J-PET scanner, built from plastic scintillators, can be calibrated using β+γ emitters and taking advantage of the fact that the direction of propagation of annihilation and prompt photons are not correlated.

758100
DOI: 10.5604/01.3001.0055.6703
15-04-2026 - Original article
Natalia Łapińska, Jakub Szlęk, Adam Pacławski, Seweryn Ulaszek, Bartek Lisowski, Aleksander Mendyk, Sebastian Polak

Objective: Neurotoxicity is undesirable property of substances, especially those reaching the central nervous system. In this study we investigated neurotoxicity by modelling two distinct endpoints: neuronal metabolic activity and electrical activity.

Methods: Based on data from in vitro experiments on human cell lines, we built predictive models using automated machine learning (AutoML) and deep symbolic optimisation (DSO), trained on six molecular representations.

Results: The mathematical equations generated using DSO outperformed AutoML models, offering superior predictive accuracy and an advantage in interpretability. The best results for electrical activity prediction were achieved with RDKit descriptors (R2 of 0.863 on the train set and 0.861 on the test set). For metabolic activity, the best model relied on MACCS fingerprints (R2 of 0.645 on the train set, 0.627 for the test set).

Conclusions: These findings highlight the potential of data-driven approaches to anticipate neurotoxicity and demonstrate that DSO can create accurate and transparent models to support the design of safer chemicals.

40461
DOI: 10.5604/01.3001.0055.6731
17-03-2026 - Original article
Emilia Majka, Rafał Walczak, Monika Łyczko, Agata Malinowska, Krzysztof Łyczko, Penelope Bouziotis, Evangelia-Alexandra Salvanou, Adamantia Apostolopoulou, Mateusz Wierzbicki, Aleksander Bilewicz, Agnieszka Majkowska-Pilip

Introduction: This study aimed to develop a novel therapeutic strategy for treatment-resistant cancers based on nano-brachytherapy, using gold nanoparticles as carriers for the Auger-electron–emitting radionuclides 197mHg and 197Hg.
Methods: Five-nanometre PEGylated gold nanoparticles were functionalised with 197mHg/197Hg via surface amalgamation and evaluated in vitro in triple-negative breast cancer (MDA-MB-231) and glioblastoma (T98G) cell lines. Cellular internalisation and subcellular distribution were assessed by uptake studies and fractionation. Cytotoxicity was evaluated using MTS assays, while therapeutic efficacy in three-dimensional models was investigated in tumour spheroids. Flow cytometry was employed to analyse apoptosis and cell-cycle distribution. DNA double-strand breaks were quantified by γ-H2AX phosphorylation. Ex vivo biodistribution studies compared intratumoural and intravenous administration routes.
Results: The radio-conjugate underwent straightforward synthesis, exhibited very high radio-labelling efficiency at low mercury loading, and maintained excellent colloidal stability. Efficient cellular uptake and pronounced nuclear accumulation were observed in both cell lines. In vitro studies demonstrated strong, time- and dose-dependent cytotoxicity predominantly mediated by apoptosis, with minimal necrosis, accompanied by significant induction of DNA double-strand breaks. In three-dimensional cultures, MDA-MB-231 spheroids underwent rapid, dose-dependent disintegration, whereas T98G spheroids displayed increased resistance. Ex vivo biodistribution revealed high tumour retention following intratumoural administration, minimal systemic exposure and predominantly renal clearance.
Conclusions: 197mHg/197Hg-functionalised gold nanoparticles represent a promising receptor-independent platform for localised nano-brachytherapy and warrant further preclinical evaluation in aggressive and therapy-resistant tumours.